Download Print this page

CYBEX VR Owner's Manual page 13

Cybex vr exercise equipment owner’s manual

Advertisement

Yearly Procedures
Replace all cables at least annually.
"As Required" Procedures
1. Inspect grips and replace as necessary.
2. Clean Range Limiting Device so that the cam tracks are wiped clean and lightly lubricated
with a Teflon base spray lubricant (Superlube®).
3. Remove Cable End Bearings and lubricate thoroughly with a medium-weight automotive
engine oil. To lubricate: Loosen rod end bearing jam nut with a 9/16" wrench. Using a 7/32"
Allen wrench, remove the socket head cap screw (SHCS) and rod end bearing from unit.
Coat bearing thoroughly with oil inside and out and reattach to unit.