Page 1
® Multi-Press Medical Owner’s Manual Strength Systems Part Number 13240-888-4 A www.cybexinternational.com...
Page 3
Cybex International, Inc. DISCLAIMER: Cybex International, Inc., makes no representations or warranties regarding the contents of this manual. We reserve the right to revise this document at any time or to make changes to the product described within it without notice or obligation to notify any person of such revisions or changes.
Cybex VR1 13240 Multi-Press Medical Owner’s Manual 1 - Safety Safety This product complies with the Eurpoean Medical Directive 93/42/EEC. Read the Owner’s manual carefully before using or servicing the equipment. It is the responsibility of the facility owner and/or owner of the equipment to instruct users on proper operation of the equipment and review all labels.
Page 8
Securely anchor each machine to the fl oor using the anchor holes provided in each machine. NOTE: Cybex is not responsible for the actual anchoring of equipment. Consult with a professional contractor. NOTE: Use fasteners having a minimum of 2,220 newtons tensile capacity.
Securing Equipment: The machine has holes in the feet, which allow for ease in anchoring to the fl oor. Cybex strongly recommends that, to eliminate rocking, tipping or falling over due to incorrect usage and misuse, equipment be secured to a solid, level surface.
Cybex VR1 13240 Multi-Press Medical Owner’s Manual Warning/Caution Decals Warning decals indicate a potentially hazardous situation, which, if not avoided, could result in death or serious injury. Caution decals indicate a potentially hazardous situation, which, if not avoided, could result in minor or moderate injury.
Page 11
Cybex VR1 13240 Multi-Press Medical Owner’s Manual Multi-Press 13240 Both Sides Description Part No. A. Warning Label....4605-381-4 B. Caution Decal....4000Y316-4 C. Caution Decal....4510-321-4 D. Caution Decal....8500-025-4 Safety Page 1-5...
Cybex VR1 13240 Multi-Press Medical Owner’s Manual Regular Maintenance Activities Preventative maintenance activities must be performed to maintain normal operation of your equipment. Keeping a log sheet of all maintenance actions will assist you in staying current with all preventative maintenance activities.
Cybex VR1 13240 Multi-Press Medical Owner’s Manual 2 - Exercise Intended Use MUSCLES USED This equipment is suitable for treatment of patients with illness or injuries and for prevention. This equipment does not possess any measurement functions. This equipment is only intended to be operated for use under the supervision of a physician, physiotherapist or physical therapist who has the requisite training and instruction.
Cybex VR1 13240 Multi-Press Medical Owner’s Manual OVERHEAD PRESS START FINISH Instructions Read and understand all instructions and warnings prior to using this machine. See Chapter 1, Safety, in the Owner’s Manual or consult with fl oor staff. Set Up 1.
Page 15
Cybex VR1 13240 Multi-Press Medical Owner’s Manual Equipment without motion limiters may only be used by patients capable of full range of motion. The equipment is not sterile and should not be used by patients with contagious diseases or open wounds.
Page 16
Cybex VR1 13240 Multi-Press Medical Owner’s Manual This page intentionally left blank Exercise Page 2-4...
All preventive maintenance activities must be performed on a regular basis. Performing routine preventive maintenance actions can aid in providing safe, trouble-free operation of all Cybex Strength Systems equipment. NOTE: Cybex is not responsible for performing regular inspection and maintenance actions for your machines.
Cybex VR1 13240 Multi-Press Medical Owner’s Manual Weekly Procedures 1. Check all nuts and bolts for looseness. Tighten as required. 2. Inspect all cables for wear or damage and proper tension. When inspecting cables, run fi ngers on the cable, paying particular attention to bends in cable and attachment points.
Page 21
Cybex VR1 13240 Multi-Press Medical Owner’s Manual 3. Inspect bars and handles for wear, paying particular attention to tab area connection points. Replace all worn handles immediately. CAUTION: Replace all worn handles immediately. Do not use if less than 1/8” of material remains to the edge.
Cybex VR1 13240 Multi-Press Medical Owner’s Manual Yearly Procedures 1. Replace all cables at least annually. Environment Static Electricity - Depending upon where you live, you may experience dry air, causing a common experience of static electricity. This may be especially true in the winter time. You may notice a static build-up just by walking across a carpet and then touching a metal object.