Summary of Contents for TriangleTube Prestige Excellence
Page 1
NOTICE tion in order to gain warranty coverage. When receiving the PRESTIGE Excellence unit, any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee. Leave all documentation received with appliance with owner for future reference.
Page 2
WARNING This manual outlines the requirements for installation of the PRESTIGE Excellence. Those require- ments include Boiler Piping, Venting/Combustion Air, Start-Up and Maintenance. For detailed instructions regarding the installation of the vent/combustion air system reference the PRESTIGE Vent Supplement and/or the various optional vent kit instructions.
Product & Safety Information Definitions The following terms are used throughout this manual to bring attention to the presence of potential hazards or important information concerning the product. NOTICE DANGER Indicates special instructions on installa- Indicates the presence of a hazardous tion, operation or maintenance, which situation which, if ignored, will result in are important to equipment but not...
Product & Safety Information DANGER WARNING Do not use this appliance if any part Should overheating occur or the gas has been under water. Immediately call supply fails to shut off, turn OFF the a qualified service technician to inspect manual gas control valve external to the appliance and to replace any part of the appliance.
Ensure the area chosen for the installation of the PRESTIGE Excellence is free of any com- For installations in Massachusetts - bustible materials, gasoline and other flamma- code requires the boiler to be installed ble liquids.
Pre-Installation Items Recommended Clearances Residential Garage Installations The PRESTIGE Excellence is approved for When installing the PRESTIGE Excellence in a zero clearance to combustibles, excluding residential garage, the following special precau- vent and boiler piping. tions per NFPA 54/ANSI Z223.1 must be taken: Mount the unit with a minimum 18 Vent &...
Antistatic fabric softeners used in clothe dryers WARNING Chlorine-type bleaches, detergents, and Do not operate a PRESTIGE Excellence cleaning solvents found in household if its combustion air inlet is located near laundry rooms a laundry room or pool facility. These...
For Direct Vent installations, involving only the BEST PRACTICES PRESTIGE Excellence, in which the minimum service clearances are maintained as listed on In order to reduce the potential risks page 4, no ventilation openings are required.
Combustion Air and Venting Methods of Accessing Combustion Air Into A inches of the bottom of the enclosure. Space - Category IV The minimum dimension of air open- ings shall be not less than 3 inches. Indoor Combustion Air Combining spaces in different stories. The volumes of spaces in different sto- NOTICE ries shall be considered as communicat-...
Combustion Air and Venting Not less than the sum of the areas of all vent connectors in the space. Fig. 3: All Combustion Air from Outdoors Through Ventilated Attic Fig. 2: All Combustion Air from Outdoors Through One Permanent Air Opening Two Permanent Openings Method.
Supplement included in the boiler installation envelope. Refer to optional DANGER vent kit instructions for additional vent installation instructions. Do not install the PRESTIGE Excellence into a common vent with other gas or oil appliances. This may cause flue gas DANGER...
DANGER the space in which the appliances remain- Do not install the PRESTIGE Excellence ing connected to the common venting sys- into a common vent with other gas or oil tem are located and other spaces of the appliances.
Combustion Air and Venting Commonwealth of Massachusetts Installations Only For direct-vent appliances, mechanical- 4. A metal or plastic identification plate vent heating appliances or domestic hot shall be mounted at the exterior of the water equipment, where the bottom of the building, four feet directly above the vent terminal and the air intake is installed location of vent terminal.
Handling Instructions 2. DO NOT mount or attempt to mount the wall bracket to hollow sheet rock or lathe The PRESTIGE Excellence is generally easier walls using anchors. Only install boiler to to handle and maneuver once removed from studs or equivalent wood structure.
Unit Preparations Wall Bracket Installation - Solid Walls 6. Reposition the bracket on the wall and align mounting slots/holes. Insert the two 1. Locate the general area of the boiler place- bolts (provided) through the mounting ment. slots/holes and loosely tighten. 2.
/ twisting. Failure Low Water Cutoff Device to support the boiler piping and connec- The PRESTIGE Excellence is equipped with tions in this manner could cause damage a factory installed pressure switch type Low to the boiler and its components.
Boiler Piping Pressure Relief Valve (Supplied with Boiler) 3/4" Street Elbow Air Vent Drain Piping Directed to a Suitable Place of Drainage CH Supply Connection CH Return Connection Fig. 5: Pressure Relief Valve Installation...
Boiler Piping Additional Limit Control Boiler System Piping Applications If a separate LWCO device is required by cer- BEST PRACTICE tain local jurisdictions or when the boiler is installed above the system piping, the follow- It is recommended on all piping applica- ing guidelines must be followed: tions to utilize a primary/secondary pip- ing arrangement as a means to provide...
System Piping - Zone Circulators nection at the same location as the expansion tank connection to the system. Connect the PRESTIGE Excellence to the sys- tem piping as shown in Fig. 9 page 21 when Diaphragm Expansion Tank zoning with zone circulators.
When To ensure adequate flow rate through pumping through with more than one zone, a the PRESTIGE Excellence, maintain a pressure differential bypass valve is required to minimum 1 inch diameter on the system avoid dead heading the pump through the post piping connecting to the boiler.
Boiler Piping System System Supply Return 12" Max. Cold Water Fill Boiler Boiler Supply Return Fig. 6: Near Boiler Piping - Diaphragm Expansion Tank 1. System circulator 6. Isolation valve 2. Automatic air vent 7. Drain/purge valve 3. Air separator 8.
Page 27
Boiler Piping System System Supply Return Cold Water Fill 12" Minimum Max. 3/4" Piping Note: Pitch horizontal pip- ing upwards (1” of pitch per 5 ft of piping) towards Boiler Boiler expansion tank. Supply Return Fig. 7 : Near Boiler Piping - Closed Type Expansion Tank 1.
Additional Zone Load Zone Load 12" Max. Fig. 9: CH System Piping - Zoning with Zone Circulators 1. PRESTIGE Excellence boiler 7. Pressure relief valve 2. CH circulator (provided) 8. Air separator 3. Flow/check valve 9. Automatic air vent 4 Isolation valve 10.
Page 29
Fig. 11: CH System Piping - Multiple Zone Valve with Single System/Boiler Circulator 1. PRESTIGE Excellence boiler 8. Air separator 2. CH circulator 9. Automatic air vent 4 Isolation valve 10.
Page 30
Note: Manifold mounted valve actuators may be used in lieu of zone valves. Fig. 13: CH System Piping - Radiant/Low Temp. Heating 1. PRESTIGE Excellence boiler 8. Air separator 2. CH circulator (provided) 9. Automatic air vent 3. Flow/check valve 10.
DANGER the ball is lost or missing, replace the entire assembly. The PRESTIGE Excellence must be vented and supplied with combustion air 3. Remove the compression nut and rubber as shown in the PRESTIGE Vent seal from the drain outlet.
Page 33
8. The PRESTIGE Excellence will typically produce a condensate that is considered slightly acidic with a pH content below 3.0. Install a neutralizing filter if required by authority having jurisdiction.
2. Install 100% lockup gas pressure regulator length and diameter requirements for natural in the gas supply line if inlet pressure can gas, based on rated PRESTIGE Excellence exceed 13”w.c at any time. Adjust the lock- input (divide by 1,000 to obtain cubic feet per up pressure regulator for 13”w.c maximum.
Fig. 17 page 30. Failure to ensure proper burner setup NOTICE could result in severe personal injury, The propane orifice requirement for death or substantial property damage. PRESTIGE Excellence is 0.204” (#52)
Gas Piping Inlet Supply Pressure Port Venturi Gas Valve Propane Orifice Gas Valve Gas Valve Pipe Fitting Gasket Fig. 17: Gas Valve / Venturi Assembly...
Fig.19. (190ºF) wire or equivalent as a minimum. 5. Push wiring tool in towards the terminal The PRESTIGE Excellence must be elec- block and insert wire in slot at bottom of trically grounded as required by National terminal block.
ELECTRICAL SHOCK HAZARD. areas of draft, lighting fixtures and fire- Before making any electrical connec- places. tions to the PRESTIGE Excellence, dis- connect electrical power supply at the 3. Set the thermostat anticipator (if applica- service panel. Failure to comply can ble) as follows: cause severe personal injury or death.
Valves with isolated end switch such as Honewell V8043 or equivalent. Additional 24V Limit Wiring Outdoor Reset Control The PRESTIGE Excellence provides 24V ter- 1. The PRESTIGE Excellence may operate minal connections for additional limit controls with a variable boiler operating tempera- as shown in Fig.
Page 42
External Wiring 4 Wire Zone Valve V.A.C. High Voltage Transformer (Power) V.A.C. Room Zone Valve Thermostat Zone 1 Room Thermostat Zone 2 Zone Valve Additional zones may Additional zones be added as shown above To Prestige 24V Terminal Strip 3 Wire Zone Valve V.A.C.
Page 43
External Wiring Thermostat Honeywell Fig. 23: Field Wiring with Zone Circulators. zone 1 R845A Relay Circulator Zone 1 Thermostat zone 2 Circulator Zone 2 Additional zones may be added as shown above To Prestige 24V Terminal Strip Thermostat Thermostat Thermostat Fig.
For areas with unusually hard water (hardness above 7 grains) consult a water treatment company. Chlorinated Water Do not use the PRESTIGE Excellence to heat a swimming pool or spa directly. Maintain the chlorine level of the water at lev- els considered safe for drinking.
The water volume of the PRESTIGE Excellence 2. Open all system isolation valves. is approximately 5 gallons (includes Boiler and DHW outer tank). Remember to include the vol- 3.
Check Low Water Cut-Off Device There should NEVER be voltage measured at the wire ends. The PRESTIGE Excellence is provided with a factory installed LWCO device that If voltage is measured at the panel under any measures system pressure of more than 10 condition, check and correct the external psi.
PRESTIGE Excellence Parameter Section of the manual starting control. on page 45 for more information. Verify the PRESTIGE Excellence and the 2. Check for loose electrical connections, boiler system is full of water and all system blown fuse...
Page 48
45 carbon monoxide emissions, which will of the PRESTIGE Excellence control result in severe personal injury or death. section on how to set the firing rate. If...
DO NOT 8. Set room thermostat(s) to desired setting(s). try to light the burner by hand. 9. The PRESTIGE Excellence control panel display Set room thermostat(s) to lowest setting. Turn the will show a sequence of numbers (0,1,2,3,4,etc.) external manual gas valve handle clockwise as the left digit.
0ºF. ily prior to the prepurge cycle. When the outdoor temperature is higher than 0ºF the PRESTIGE Excellence con- 1140 ] This is the prepurge cycle. The trol will calculate the target temperature...
Start-Up Procedures digits on the display shows the DHW stor- 3140 ] This is the normal operation cycle. age temperature setting. After the flame is proven and stabilized the burner will fire at low input for 3. Press the “+” or “-” button to change the approximately 1 minute.
Start-Up Procedures Boiler Control Display 4180 ] This indicates normal operation for DHW. The burner will begin modulat- Standby Mode StbY ing its input based on the length of demand by the DHW setting. The burner will not go After the boiler is turned on, the control panel into the low input rate for the 1 minute will display STANDBY mode as shown in the flame stabilization period that occurs in CH...
Page 53
Start-Up Procedures Standby Mode Display TO TEMPORARILY PLACE THE BURN- ER INTO LOW FIRE TEST MODE: press Display Boiler function StbY the MODE button until “ ” is displayed. Then press and hold both the mode and “-” but- STANDBY, no demand for heat ton simultaneously until the first digit flashes Fan prepurge (10 seconds) or post purge cycle “L”.
Start-Up Procedures Setting The Boiler Parameters Note 3: This parameter should not be changed from the factory setting of “01”. The perfor- mance of the CH (Central/Space Heating) will Parameter mode be affected and can become unreliable. Accessing Boiler Information To access PARAMETER mode when the sys- Information mode tem is in STANDBY mode, press the MODE...
Start-Up Procedures Error (Hard Lockout) Mode Display Hard Lockout If a system fault occurs while the boiler is run- E 00 Flame detected prior to burner startup ning, the system goes into lockout and the dis- Failed ignition after 5 attempts play starts to flash with the first digit as an E and the next two digits give the code for this Gas valve harness not properly connected...
Outdoor Reset Control SECTION XI - Outdoor Reset Control 8. Tap the enclosed plastic anchors into the pilot holes. Use care not to damage the anchors. Plastic Anchors (2) Sensor Enclosure Mounting Screws(2) 9. Mount the sensor enclosure using the screws provided.
Outdoor Reset Control Summer / Winter Switch at Boiler • The boiler target temperature setpoints are based on outdoor air temperatures between 0ºF and 68ºF and are linearly proportional. If required the CH (Central Heating) system See Graph 1 and Table 3 on page 51 for a can be turned off at the boiler, similar to man- sample setting.
Page 58
Outdoor Reset Control Parameter 4 Set Point Outdoor Air Temperature ( F) Graph 1: Outdoor Air Temperature Reset Curve (Example) Table 3: Outdoor Air Temperature Reset (Example) Outdoor Boiler Target Temp. Temperature Based on Outdoor Temp. 0ºF or Lower 140ºF 23ºF 122ºF 40ºF...
53. Reviewed all instructions shipped with the Check-out Procedures PRESTIGE Excellence with the homeown- er or maintenance personnel. Boiler system water chemistry checked and verified as outlined on page 37. Completed the Installation Record on page...
Installation Record SECTION XIII - Installation Record PRESTIGE Excellence Model Number: Serial Number: Date of Installation: Fuel: Natural Gas Propane Measured Rate of Input: Btu/hr Combustion Readings: The following items were completed during installation: Installation instructions have been followed and completed...
Maintenance Schedule SECTION XIV - Maintenance Schedule Owner Maintenance Service Technician Periodically: At least on an annual basis the following main- Check the area around the unit. tenance should be performed by a qualified ser- Check and remove any blockage from the vice technician: combustion air inlet and ventilation open- General...
WARNING area. The PRESTIGE Excellence should be inspected and serviced annually, prefer- Inspect Burner Area ably at the start of the heating season, by a qualified service technician. In addi-...
Maintenance Procedures Clean Condensate Drain Assembly Inspect Vent and Combustion Air Piping 1. Loosen the slip ring nut from the conden- Visually inspect the venting system and com- sate drain assembly disconnecting the bustion air piping for blockage, deterioration assembly from the boiler. or leakage.
Maintenance Procedures Check Expansion Tank WARNING Refer to Section IV - Boiler Piping for rec- Before manually operating the pressure ommended location of the expansion tank relief valve, ensure the discharge piping is and air eliminators. directed to a suitable place of disposal to avoid a potential scald hazard.
Maintenance Procedures Check Control Wiring Carefully remove the burner mounting plate assembly from the heat exchanger. Ensure Inspect all control wiring. Ensure wiring is in combustion chamber insulation is not damaged good condition and properly connected. during removal of burner mounting plate assembly.
Maintenance Procedures Check Flame Signal 2. Allow the boiler to cool down to room tem- perature before servicing. The flame signal should be a min. 3µ Α −DC. 3. Disconnect the gas piping and rectifier plug to the gas valve. Check the ignitor for fouling or damaged insulation if a low flame signal is read.
Maintenance Procedures Review With Owner 14. Attach a hose to the boiler drain valve and flush the boiler thoroughly with fresh water Ensure the owner understands the impor- by using the purge valves to allow water to tance to perform the maintenance schedule enter through the make-up water line to the specified in this manual.
Page 76
Graph 2: Pressure Drop Comparison Excellence 110 vs Grundfos UPS 15-58F-FC Available System Head in Feet Delta T Spd 1 Spd 2 Spd 3 11.2 10.9 14.2 Note: Minimum allowable flow rate at full input: 5.0 gpm...
Page 77
Additional Quality Water Heating Equipment Available from Triangle Tube Maxi-Flo and Spa Heat Exchangers Construction of high quality corrosion resistant stainless steel (AISI 316) or titanium Specially designed built-in flow restrictor to assure maximum heat exchange Compact and light weight Available in 5 sizes that can accommodate any size pool or spa Smart Indirect Fired Water Heaters...