Table of Contents

Advertisement

Customer must register unit within thirty (30) days of installation in order to gain warranty coverage. See Warranty Card
for details.
Leave all documentation received with appliance with the owner for future reference.
To maintain the safety & longevity of your appliance, read and follow the maintenance schedule
information throughout this manual.
If the information in this manual is not followed exactly, a fire or explosion may result causing sub-
stantial property damage, serious injury, or death.
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
• WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
- If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Revision date : 03/15/18
User's Information Manual
PRESTIGE
NOTICE
NOTICE
WARNING
FOR YOUR SAFETY
A1005230 - 664A0800 • B
Solo PA 80, 110, 155, 175, 250, 299, 399
Excellence 110

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRESTIGE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for TriangleTube PRESTIGE Series

  • Page 1 User’s Information Manual PRESTIGE Solo PA 80, 110, 155, 175, 250, 299, 399 Excellence 110 NOTICE NOTICE • Customer must register unit within thirty (30) days of installation in order to gain warranty coverage. See Warranty Card for details. • Leave all documentation received with appliance with the owner for future reference.
  • Page 2 INTENTIONALLY LEFT BLANK...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS PRODUCT AND SAFETY INFORMATION ................V CHAPTER 1 - COMBUSTION AIR CONTAMINATION ............1 CHAPTER 2 - MAINTENANCE SCHEDULES ..............3 2.1. Service Technician ..........................3 2.2. Owner Maintenance ........................3 CHAPTER 3 - MAINTENANCE PROCEDURES ..............5 3.1. Owner Maintenance Procedures ....................5 3.2.
  • Page 4 INDEX OF ILLUSTRATIONS Fig. 1 - Condensate Drain Assembly ......................6 Fig. 2 - ACVMax User Interface .........................11 Fig. 3 - PRESTIGE Solo 80/110 Jacket Components ................25 Fig. 4 - PRESTIGE Solo 155/175/250 Jacket Components ..............26 Fig. 5 - PRESTIGE Solo 299/399 Jacket Components ................27 Fig.
  • Page 5: Product And Safety Information

    PRODUCT AND SAFETY INFORMATION STOP ! IMPORTANT SAFETY INFORMATION FOR READ BEFORE SERVICING THE HOMEOWNER AND THE TECHNICIAN Failure to adhere to the guidelines within this manual This manual contains important information with respect to can result in substantial property damage, serious the operation and maintenance of the appliance.
  • Page 6 • Triangle Tube reserves the right to change the technical characteristics, components and features of its products without prior notice. Check for an updated version of this manual at www.triangletube.com.
  • Page 7 PRODUCT AND SAFETY INFORMATION PRODUCT EFFECTIVITY PRESTIGE SOLO 299/399 NOTICE Following a configuration upgrade on the Pres- tige Solo 299 and 399 blower/Venturi/gas valve assembly, two different configurations now exist in the Prestige Solo 299/399 boilers. To re- flect the differences, a code (see table below) is allocated to each configuration and displayed in the relevant locations in the manual.
  • Page 8 INTENTIONALLY LEFT BLANK...
  • Page 9: Chapter 1 - Combustion Air Contamination

    CHAPTER 1 - COMBUSTION AIR CONTAMINATION Potential contaminating products WARNING • Spray cans containing chloro/fluorocarbons If the PRESTIGE combustion air inlet is located • Permanent Wave Solutions in an area likely to cause or contain contamina- • Chlorinated wax tion, or if products which could contaminate the air cannot be removed, the combustion air •...
  • Page 10 INTENTIONALLY LEFT BLANK...
  • Page 11: Chapter 2 - Maintenance Schedules

    CHAPTER 2 - MAINTENANCE SCHEDULES 2.2. Owner Maintenance 2.1. Service Technician Periodically: At least on an annual basis the following maintenance should be performed by a qualified service technician: • Check the area around the unit. • Check and remove any blockage from the combus- General tion air inlet and ventilation openings.
  • Page 12 INTENTIONALLY LEFT BLANK...
  • Page 13: Chapter 3 - Maintenance Procedures

    CHAPTER 3 - MAINTENANCE PROCEDURES 3.1. Owner Maintenance Procedures • Verify that the area surrounding the PRESTIGE is free of combustible / flammable materials or flam- mable vapors or liquids. Remove immediately if WARNING found. The PRESTIGE must be inspected and ser- •...
  • Page 14: Monthly Maintenance

    CHAPTER 3 - MAINTENANCE PROCEDURES 3.3. Monthly Maintenance 4. Ensure the condensate drain tubing is not blocked by pouring water through the fill plug port on the condensate drain assembly. The water should flow 3.3.1 Check Vent and Combustion Air Piping out of the end of the drain tubing.
  • Page 15: 6-Month Maintenance

    CHAPTER 3 - MAINTENANCE PROCEDURES 3.4. 6-Month Maintenance 3. If water flows freely, release the lever and allow the valve to seat. Watch the end of the relief valve dis- charge pipe to ensure that the valve does not weep 3.4.1 Check Water and Gas Piping after the line has had time to drain.
  • Page 16 INTENTIONALLY LEFT BLANK...
  • Page 17: Chapter 4 - Operating Instructions

    CHAPTER 4 - OPERATING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result, causing substantial property damage, serious injury, or death. A. This appliance does not have a pilot. It is equipped C.
  • Page 18 INTENTIONALLY LEFT BLANK...
  • Page 19: Chapter 5 - Acvmax Operation

    CHAPTER 5 - ACVMAX OPERATION 5.1. ACVMax Navigation The ACVMax Boiler Management System is designed to be flexible yet easy to use. ACVMax monitors and Navigation is performed through four arrow buttons controls the PRESTIGE to provide heat as efficiently as UP, DOWN, LEFT, RIGHT with a center OK button for possible.
  • Page 20: Acvmax Menu Structure

    CHAPTER 5 - ACVMAX OPERATION 5.2. ACVMax Menu Structure Home Screen Solo 186°F 156°F Target = 186°F DHW Demand EZ Setup CH / DHW Operation Select Language Boiler Information Heating Enabled Boiler Information Lockout History Select Language English Français Nederlands Español Italiano Deutsch...
  • Page 21: Home Screen

    CHAPTER 5 - ACVMAX OPERATION 5.3. Home Screen Main Icons of ACVMAX display • Central Heating - indicates information related The Home Screen presents status information in a very to central/space heating. user friendly way so that the current state of the boiler can be quickly accessed.
  • Page 22: Status Line Messages

    CHAPTER 5 - ACVMAX OPERATION 5.4. Status Line Messages CH Post Pump - The central heating circulator(s) is/are running to remove heat from the Prestige at the com- Standby - Indicates that the Prestige is ready to re- pletion of a call. spond when a demand is received.
  • Page 23: Main Menu

    CHAPTER 5 - ACVMAX OPERATION 5.5. Main Menu 5.6. EZ Setup The Main Menu can be entered from the Home Screen The EZ Setup menus provide a simple way to quick- by pressing the OK button. ly customize ACVMax for each installation. EZ Setup prompts the user to make selections which allows the The menu system utilizes icons to represent each selection.
  • Page 24: Ch / Dhw Operation

    CHAPTER 5 - ACVMAX OPERATION 5.7. CH / DHW Operation The CH / DHW Operation Menu can be entered from the Main Menu by selecting the CH / DHW Operation icon and pressing the OK button. The CH / DHW Operation Menu provides a simple way to disable either the central heating or domestic hot water functions of the Prestige.
  • Page 25: Language Selection

    CHAPTER 5 - ACVMAX OPERATION 5.8. Language Selection The Select Language Menu can be entered from the Main Menu by selecting the Select Language icon and press- ing the OK button. The Select Language Menu provides a simple way to select the language used on the display (nine different languages: English, French, Dutch, Spanish, Italian, German, Czech, Polish and Russian).
  • Page 26: Boiler Information

    CHAPTER 5 - ACVMAX OPERATION 5.9. Boiler Information Boiler Information can be viewed by selecting the Boiler Information icon and pressing the OK button. Boiler Information provides real time operating information of the Prestige. Boiler Information Boiler Information Boiler Information displays six Boiler Information boiler readings at a time.
  • Page 27: Information Items

    CHAPTER 5 - ACVMAX OPERATION 5.9.1 Information Items Information Item Description Displays the current operating state of the Prestige. This is the same as the status Boiler Status line on the home screen. Heating Call Displays if a central heating call is present. DHW Call Displays if a domestic hot water call is present.
  • Page 28: Lockout History

    CHAPTER 5 - ACVMAX OPERATION 5.10. Lockout History Lockout History can be viewed by selecting the Lockout History icon and pressing the OK button. The Lockout History Screen lists the last eight lockouts along with how long ago they occurred. Boiler Information Lockout History Lockout History displays the last...
  • Page 29: Lockout Screen

    CHAPTER 5 - ACVMAX OPERATION 5.10.1 Lockout Screen If a problem occurs, the Lockout Screen replaces the Home Screen. The backlight will remain on until the lockout is reset. Pressing any arrow button will return to the Home Screen so that additional troubleshooting can be performed. See Sections 5.10.2 on page 22 and 5.10.3 on page 23 for a list of lockouts and descriptions.
  • Page 30: Manual Reset Lockouts

    CHAPTER 5 - ACVMAX OPERATION 5.10.2 Manual Reset Lockouts Code Lockout Message Description Failed Ignition The burner failed to light after 5 ignition attempts. False Flame Flame detected prior to ignition. High Boiler Temperature Boiler temperature has reached 210°F [99ºC] or 102°F [39°C]. Blower Speed Blower is not at correct speed or speed signal is not being received by control module.
  • Page 31: Automatic Reset Blocking Lockouts

    CHAPTER 5 - ACVMAX OPERATION 5.10.3 Automatic Reset Blocking Lockouts Code Lockout Message Description High Flue Temperature Flue temperature exceeds high limit. Internal Control Fault EEPROM misconfiguration. Internal Control Fault CRC check error. DHW Sensor Shorted A short circuit has been detected in the DHW temperature sensor circuit. DHW Sensor Open An open circuit has been detected in the DHW temperature sensor circuit.
  • Page 32 INTENTIONALLY LEFT BLANK...
  • Page 33: Chapter 6 - Replacement Parts

    Use only genuine Triangle Tube replacement parts to ensure warranty coverage and to avoid improper operation or damage to appliance. • Contact Triangle Tube at 856-228-8881 or www.triangletube.com for a list of distributors near you. Fig. 3 - PRESTIGE Solo 80/110 Jacket Components...
  • Page 34: Fig. 4 - Prestige Solo 155/175/250 Jacket Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 4 - PRESTIGE Solo 155/175/250 Jacket Components Item Part # Description PAJKT01 Front Jacket Panel (with insulation) PAJKT03 Left Side Jacket Panel (with insulation) PAJKT21 Right Side Jacket Panel (with insulation) PAJKT12 Top Panel PSRKIT21 Wall Mounting Bracket with Hardware...
  • Page 35: Fig. 5 - Prestige Solo 299/399 Jacket Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 5 - PRESTIGE Solo 299/399 Jacket Components Item Part # Description PAJKT15 Front Jacket Panel (with insulation) PAJKT16 Left Side Jacket Panel (with insulation) PAJKT22 Right Side Jacket Panel (with insulation) PAJKT17 Top Panel - Front PAJKT18 Top Panel - Rear PSRKIT21...
  • Page 36: Fig. 6 - Prestige Excellence 110 Jacket Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 6 - PRESTIGE Excellence 110 Jacket Components Item Part # Description PAJKT15 Front Jacket Panel (with insulation) PAJKT16 Left Side Jacket Panel (with insulation) PAJKT22 Right Side Jacket Panel (with insulation) PAJKT25 Top Panel PSRKIT21 Wall Mounting Bracket with Hardware...
  • Page 37: Fig. 7 - Prestige Solo 80/110 Internal Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 7 - PRESTIGE Solo 80/110 Internal Components Item Part # Description PARKIT90 Heat Exchanger Body PTADPT07 Vent Outlet/Combustion Air Inlet Adapter PARKIT02 Polypropylene Vent Pipe PTRKIT123 Supply/Return Temperature Sensor PARKIT01 Flue Temperature Sensor PARKIT04 LWCO Pressure Sensor PARKIT05 Condensate Drain Assembly...
  • Page 38: Fig. 8 - Prestige Solo 155/175/250 Internal Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 8 - PRESTIGE Solo 155/175/250 Internal Components Item Part # Description PARKIT91 Heat Exchanger Body Solo 155 PARKIT92 Heat Exchanger Body Solo 175 PARKIT93 Heat Exchanger Body Solo 250 PTADPT07 Vent Outlet/Combustion Air Inlet Adapter PARKIT08 Polypropylene Vent Pipe PTRKIT122...
  • Page 39: Fig. 9 - Prestige Solo 299/399 (Œ) Internal Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 9 - PRESTIGE Solo 299/399 (Œ) Internal Components NOTICE Internal components of Prestige Solo 299/399 () are identical, except the blower/Venturi/gas valve assembly. Refer to Fig. 14 on page 36 for details. Item Part # Description PARKIT94 Heat Exchanger Body Solo 299...
  • Page 40: Fig. 10 - Prestige Excellence 110 Internal Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 10 - PRESTIGE Excellence 110 Internal Components Item Part # Description PARKIT90 Heat Exchanger Body PTADPT07 Vent Outlet/Combustion Air Inlet Adapter PARKIT03 Polypropylene Vent Pipe PTRKIT123 Supply/Return Temperature Sensor PARKIT01 Flue Temperature Sensor PARKIT04 LWCO Pressure Sensor PARKIT05 Condensate Drain Assembly...
  • Page 41: Fig. 11 - Prestige Solo 80/110 / Excellence 110 Burner Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 11 - PRESTIGE Solo 80/110 / Excellence 110 Burner Components Item Part # Description PARKIT12 Combustion Chamber 2-in-1 Insulation PARKIT14 Burner Head Assembly (with Gasket) PARKIT11 Blower Assembly (with Gasket) PARKIT18 Blower Clamp PARKIT19 Blower Gasket PARKIT15 Burner Plate Assembly...
  • Page 42: Fig. 12 - Prestige Solo 155/175/250 Burner Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 12 - PRESTIGE Solo 155/175/250 Burner Components Item Part # Description PARKIT42 Combustion Chamber 2-in-1 Insulation - Solo 155 PARKIT52 Combustion Chamber 2-in-1 Insulation - Solo 175 & 250 PARKIT54 Burner Head Assembly (with Gasket) PARKIT51 Blower Assembly (with Gasket) - Solo 155 &...
  • Page 43: Fig. 13 - Prestige Solo 299/399 (Œ) Burner Components

    CHAPTER 6 - REPLACEMENT PARTS Fig. 13 - PRESTIGE Solo 299/399 (Œ) Burner Components Item Part # Description PARKIT72 Combustion Chamber 2-in-1 Insulation PARKIT74 Burner Head Assembly (with Gasket) PARKIT71 Blower Assembly (with Gasket) PARKIT18 Blower Clamp PARKIT19 Blower Gasket PARKIT75 Burner Plate Assembly PTRKIT112...
  • Page 44 CHAPTER 6 - REPLACEMENT PARTS  Fig. 14 - PRESTIGE Solo 299/399 ( ) Burner Components Item Part # Description PARKIT72 Combustion Chamber 2-in-1 Insulation PARKIT74 Burner Head Assembly (with Gasket) TCRKIT16 Blower Assembly PARKIT18 Blower Clamp PARKIT19 Blower Gasket PARKIT75 Burner Plate Assembly TCRKIT18...
  • Page 45: Fig. 15 - Prestige Solo Control & Display Enclosures

    CHAPTER 6 - REPLACEMENT PARTS Fig. 15 - PRESTIGE Solo Control & Display Enclosures Item Part # Description PTRKIT109 Pressure Gauge PTSWI01 Power Switch PTSWI02 Power Switch Cover PARKIT101 Display Module PARKIT100 Control Module (Universal when used with PARKIT101) PAHNG01 Control Box Hinges...
  • Page 48 Additional quality water heating equipment available from Triangle Tube Maxi-Flo Pool and Spa Heat Exchangers • Constructed of high quality corrosion resistant stainless steel (AISI 316) or titanium • Specially designed built-in flow restrictor to assure maximum heat exchange • Compact and light weight •...