TriangleTube Prestige PARKIT101 Manual

Display module replacement

Advertisement

Prestige
Display Module Replacement
Kit Part Number
PARKIT101
Each Kit Includes:
• Display Module
• (6) Screws
WARNING
!
Indicates a potentially hazardous situation which,
if ignored, can result in serious injury or substan-
tial property damage.
WARNING
!
For your safety, turn off electrical power supply
at service panel and allow unit to cool before pro-
ceeding to avoid possible electrical shock and
scald hazard. Failure to do so can cause severe
personal injury or death.
2020-20 Prestige Display Module Replacement
Revised 1/22/2020
Description
Display Module Replacement
Recommended Tools:
• Flathead Screwdriver
• Phillips Head Screwdriver
NOTICE
Indicates special instructions on installation, operation
or maintenance, which are important to equipment
but not related to personal injury hazards.
!
Failure to follow instructions below can result in
severe personal injury or damage if ignored.
Model
All Models
WARNING
Instructions are for a qualified installer/ ser-
vice technician only.
Read all instructions before proceeding.
Follow instructions in proper order.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Prestige PARKIT101 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TriangleTube Prestige PARKIT101

  • Page 1 Prestige Display Module Replacement Kit Part Number Description Model PARKIT101 Display Module Replacement All Models Each Kit Includes: Recommended Tools: • Display Module • Flathead Screwdriver • (6) Screws • Phillips Head Screwdriver NOTICE WARNING Indicates special instructions on installation, operation Indicates a potentially hazardous situation which, or maintenance, which are important to equipment if ignored, can result in serious injury or substan-...
  • Page 2 Prestige Display Module Replacement 1. Preliminary Instructions: 1. Verify that the Display Module replacement kit is correct for the model of boiler. See table on page 1. 2. Carefully open and unpack the PARTS BOX from its shipping carton. 3. Carefully remove and check for any damage. NOTICE Fig.
  • Page 3 Prestige Display Module Replacement 10. Press the UP and DOWN buttons to scroll through the various settings and record all Boiler Settings in Table 1. Once completed, press the RIGHT but- ton to highlight the Previous Screen icon, then press the OK button. NOTICE Perform the following steps if the Instinct is part of a Cascade System or the System Temperature Sensor is being used on a...
  • Page 4 Prestige Display Module Replacement 5. Remove all 6 screws hold the old display module in place. 6. Leave the rubber insert installed in the cover. 7. Remove the display module from the boiler. 4. Installation of Display Module 1. Place the new display module with the screen aligned in the cutout in the front cover, ensuring all of the tabs of the rubber insert fit in the appro- priate cutout.
  • Page 5 Prestige Display Module Replacement Table 1: Controls Settings HEATING SETTING FACTORY DEFAULT MINIMUM SETTING MAXIMUM SETTING EXISTING SETTING Heating Operation Enabled Demand Type Thermostat & Outd. Curve Absolute Max CH Setpoint 185°F [85°C] 68°F [20°C] 188°F [87°C] CH1 Maximum Setpoint 180°F [82°C] 68°F [20°C] 188°F [87°C] CH1 Minimum Setpoint 80°F [27°C] 60°F [15°C]...
  • Page 6 Prestige Display Module Replacement Table 1 Cont: BOILER SETTING FACTORY DEFAULT MINIMUM SETTING MAXIMUM SETTING EXISTING SETTING Lockout Temp. 210°F [99°C] Modbus Address 0=BCST 0=BCST Flex. Relay 1(CH) Flex. Relay 2(DHW) Flex. Relay 3(P3) CH1/CH2/DHW Flex. Relay 4(ERR) ERROR Flex. Relay 5(Flame) FLAME Flex. Relay 6(P4) Error Relay On Lockout, Blocking and Warning...

Table of Contents