Users' Menu - PEERLESS Combi 160 Installation, Operation & Maintenance Manual

Gas boiler
Table of Contents

Advertisement

12 - USE
12.16 - "Users'
menu"
When entering the "Users' menu", the
display, item "1" in fi gure 37, will start
blinking indicating that a change of
mode has taken place. To access the
"Users' menu" (see also section 16 to
better understand the several menus):
press the
button for 2
seconds until the display starts
blinking;
press and release the
several times until the desired
parameter is displayed;
PARAMETER
DESCRIPTION
Adjustment of the curve angel as shown in
fi gures 38 and 39 when outdoor reset is active
per section 12.9.
Adjustment of the "Minimum heating
temperature" as shown in fi gures 38 and 39
when outdoor reset is active per section 12.9.
Adjustment of the "Maximum heating
temperature" as shown in fi gures 38 and 39
when outdoor reset is active per section 12.9.
Adjustment of the parallel shift of the curve as
shown in fi gures 38 and 39 when outdoor reset
is active per section 12.9.
Display of the calculated heating temperature
when outdoor reset is active per section 12.9,
or display of the temperature set by knob "7"
shown in fi gure 37.
Display of the domestic hot water temperature
when set by knob "11" shown in fi gure 37.
Display of last error code registered, section
12.18.2
Display of last lockout occurred, section 12.18.1
use the
change the value of the selected
parameter.
press
change before going to the next
parameter.
When the last parameter has been
reached and the
pressed, the display will stop blinking
indicating exit from the menu.
button
or
keys, to
to save the parameter
button
INFORMATION ON DISPLAY ITEM "2" of fi gure 37
Setting range: 0,1 to 5,0
Setting range: see section 12.10.3
Setting range: see section 12.10.3
The adjustment is made by turning knob "7" shown
in fi gure 37. The selected curve can be shifted up
or down by 18 °F (10 °C).
Temperature display only with a range between 68
°F (20 °C) and 189 °F (87 °C).
Temperature display only with a range between 104
°F (40 °C) and 158 °F (70 °C), see section 12.7
Error code display per section 12.18.2
Fault code per section 12.18.1
50
NOTE: If no key is pressed for
more than 60 seconds, the control
automatically exits the "Users'
menu". Any parameter change not
saved using the
be lost.
The table below lists each "Users'
menu" parameter, what it affects and
its adjustment range.
button, will

Advertisement

Table of Contents
loading

Table of Contents