WBV/WV
Boilers
Installation,
Operation
Maintenance
Manual
PEERLESS"
CAST
IRON
BOILERS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WBV SERIES and is the answer not in the manual?

Questions and answers

MaryAnn Pulaski
March 13, 2025

How do I increase the temp of water? My water is only luke warm. It has been much hotter in the past.

User image 67d2f47f5722b
1 comments:
Mr. Anderson
March 13, 2025

To increase the water temperature in a PEERLESS WBV SERIES boiler, follow these steps:

1. Adjust the thermostat or aquastat – Ensure the boiler’s temperature control is set to the desired range, typically between 180-200°F.
2. Check the burner operation – Ensure the burner is functioning correctly and providing adequate heat.
3. Verify water flow – Open the make-up water valve to allow a steady flow of water while maintaining the correct temperature range.
4. Inspect for system blockages – Clean the boiler to remove any oil, grease, or sludge that could affect heat transfer.
5. Ensure proper venting – Make sure the flue is clear and correctly configured for optimal performance.

Be cautious not to increase the temperature beyond safe limits to avoid overheating or damaging the boiler.

This answer is automatically generated

Barb
January 21, 2025

How to fill radiators with water

1 comments:
Mr. Anderson
May 14, 2025

To fill PEERLESS SERIES radiators with water:

1. Ensure the boiler water level is correct by checking the sight glass.
2. Open the system's water supply valve to allow water into the boiler.
3. As the boiler fills, air will be pushed out through air vents on the radiators.
4. Monitor pressure and water level. Do not overfill.
5. Once water reaches the proper level and air is purged, close the fill valve.

Note: Do not fill radiators directly; they fill automatically from the boiler.

This answer is automatically generated

Summary of Contents for PEERLESS WBV SERIES

  • Page 1 WBV/WV Boilers Installation, Operation Maintenance Manual PEERLESS" CAST IRON BOILERS...
  • Page 2 Packaged or Knockdo , 8 Sizes Sections to 2.00 GPH Input 82% to 86% AFUE Natural Draft (chimney) Venting Factory Assembled Sections on Knockdown Boilers • Reduces Installation Time in 3 and 4 Section for Hot Water or Steam • Convertible from Rear to Top Flue for...
  • Page 3 Background Information - Draft Requirements Modern boilers operate with higher efficiencies than older boilers. Smaller flueways, as well as bars, pins and fins are designed into modern boilers to transfer as much heat as possible from the hot gases to the water or steam and prevent heat loss up the chimney.
  • Page 4 INSTALLATION INSTRUCTIONS- SERIESWBV and WV Read carefullybefore beginningwork. I t willsavetime.Studythe includeddrawings. The equipmentshall be installed inaccordancewiththoseinstallationregulationsin forcein the localarea wherethe installationis to be made,including the currenteditionof NFPA-31. T heseshall be carefullyfollowedinall cases.Authoritieshavingjurisdictionshall be consultedbeforeinstallations are made. The boiler mustbe installedby a qualifiedcontractor. The boiler warrantycan be voidedif the boileris not installed,maintainedandservicedcorrectly.
  • Page 5 E - PIPING DO NOT PIPEBOILERBEFOREJACKET_SINSTALLED. 1- See Figures1 and2 forsuggestedpipingto the boiler. 2 - Makeup cold watersupply connectionto the boiler. 3 - Installpressuregaugeor pressure-temperature g augein tappingprovided.See page3. 4 - Plugal_open tappingsin the boilerand fill with water.Apply approximately thirty (30) poundspressure.Checkto make certainthat all ioints and fittings are watertight.
  • Page 6 WBV/WV WATERBOILER SAFETY RELIEF VALVE 11/16" -_-_2,18" 7 3 1/16" _ 1 I/2" SUPPLY_ 1 114" • 6" REAR OPTIONAL TANKLESS FLUE "C" HEATER _(WBV-O3, WBV-04 ONLY) LIMIT "C'"DOLATO" TEMPERATURE PRESSURE .35" VALVE GAUGE DRAIN VALVE LINE 28 I/2" 1_ 3/_ I_- DRAIN VALVe"...
  • Page 7 HIGH TEMPERATURE HIC.H TCMPCRATUR_" HEATER V4" CONTROl_ MIXED "TAPPING 3/4" CONTROL HEATER i2 _ MiN° MIN. FLOW CONTROL WATER INLET MIXER COLD WATER INLET FIGURE4 FIGURE5 7 -Tankless WaterHeater Whenwaterheateris not employed,coverthe heateropeningwith coverplate(Item7 or 16) BESURERUBBERGASKETIS IN PLACEBETWEENCOVERPLATEOR WATERHEATERPLATEAND BOILERSECTION. 8- StorageTank Heater- if a waterboileris to be usedin conjunctionwitha storagetank heaterreferto Figure6 fortypicalpiping.Alsoreferto additional instructionssuppliedwith tank, THREE...
  • Page 8 FIGURE7: STEAMBOILERS FIGURE8: WATERBOILERS (See page 13for parts identification)
  • Page 9 F- OIL BURNER INSTALLATION 1-The oil burner is suppliedwitha mountingflangefixed in position. 2 - Mountthe burner to the combustionchambercoverplate(Item5) withfour (4) 5/r6"studs and nuts provided. BE SUREHI TEMPGASKETIS BETWEENTHE BURNERMOUNTINGFLANGEAND THE COMBUSTION CHAMBERCOVERPLATE. 3 - Caremustbe takenwhen routingthe oil lines so not to interferewith the openingand closingof the door.Flexibleoil linesor flared copperdiscon- nects withvalves(whencopperlinesare used) may be installedto assurefull openingof the door when servicing.
  • Page 10 F - OIL BURNERINSTALLATION (continued) RIELLOSERIES40 OIL BURNER Boiler Burner Nozzle ** Pump Turbulator AirDamper Model No. Model N O. Size Pressure Setting Setting WBV-03-060 0.50 90° B WBV-03-085 0.65 60" W 2.45 WBV-03-110 0.85 60° W WBV-04-125 1.0060° W WBV-04-140 1.1060°...
  • Page 11 WARNING:Improperinstallationof burner harnesscan allowburnerto energizewithswingdoor open, creating a severeburn hazardto boiler maintenance personnel 4a - Locate the polarized burner harness in the burner carton. Attach harness betweenburner andjunction box. SeeJunction Box detail (Figure9), photos(Figure 10& cover),and wiringdiagrams(Figures11-13). 4b.- If using a non-Peerlesssuppliedburner,obtain appropriateburner harnessfrom a PeerlessDistributor, o r hardwireburner such that burner swing door can not be openedwithoutdisconnecting power.
  • Page 12 _GNITOR BC4LER GROUND _OUNO _GROUNB SCREW SCREW ADDITIONAL <_ BURNER UMIT SAFETY TCHES i-1- , _= LIMIT LBURNER SER_C[ S_TCH BI_NEBT INSTAL_.[R) STEAM WITH OR (HOT) WITHOUTHEATERTANKLESS L2L•_ $5/60/I FUSED DISCONNECT INSTALLER) _HERMOSTAT --LINE VOLTAGE OPERATING CONTROL ... VOLTACE FOR STEAU W/ TANKLESS HEATI_R ONLy VelRING MUST COMPLY...
  • Page 13 CIRCULATOR LINE VOLTAGE VOLTAGE NOTE: WIPING MU_T COMPLY WITH APPLICABLE ZONE #l ZONE _B ZONE _3 CODES,ORDINANCES_AND REGULATIONS. FIGURE14: ZONINGWITHCIRCULATORS © iBOV - 6OMZ MAIN DISCONNECT 12o/z4v SOHZ 4OVA _LIL2 WIRING MUST COMPLY WITH APPLICAI__E CODES I ORDINANCES t AND REGULATIONS FIGURE15: ZONINGWITHZONEVALVES...
  • Page 14 _O ZONE SPACE HE ATIN_ THERMOSTAT MAIN ,r_-A _" DISCONNECT ---(9 TO PEERLESS ® PARTNER C:RCULAiOR BOILER LIMIT HONEYWELL LB148A LINE VOLTAGE ..VOLTAGE TO BOILER TO BURNER CIRCULATOR DISCONNECT FIGURE16:PARTNER WITHCIRCULATOR (NON-PRIORITY) I - CLEANING THE STEAM SIDE(SKIMMING) Cleanthe boiler withinone week after initialstart-up.Cleaningwill be moreeffectiveif boileroperatesa day or twoto loosensedimentand impuritiesin system.
  • Page 15 J - CLEANING HEATINGSURFACES NOTE:BOILERISTO BE CLEANEDATLEASTONCEA YEAR.TOTHOROUGHLY CLEANTHE BOILERIT MUST BE BRUSHEDDOWNFROMTHE TOE ALTERNATELY, FOR LIMITED SPACE OR MINIMUM CLEARANCETO COMBUSTIBLEINSTALLATIONS, CLEANING THE HEAT EXCHANGER FROMTHE COMBUSTION CHAMBERSIDE IS ACCEPTABLE. TO CLEAN: 1 Turnoff all electricalpowerto the boiler beforebeginningcleaningoperation. 2 - Removetop jacket paneland flue collectorcoverplate,item 11.
  • Page 16 REPAIR PARTS SERIES WBV/WV OIL BOILERS REPAIR PARTS ARE AVAILABLEFROMYOUR INSTALLER OR BY CONTACTING PEERLESS HEATERCOMPANY,BOYERTOWN,PA 19512-1021 NOTE: REMEMBER TO INCLUDE BOILER MODEL NUMBER AND SERIAL NUMBER WHEN ORDERING PARTS ItemNo.** StockCode Additional Information Description Block Assembly Water(Open) SpecifySize BlockAssemblyWater(Closed) SpecifySize BlockAssemblySteam (Open) SpecifySize...
  • Page 17 Series WBV/WV OH Boilers Installation, Operation Maintenance Manual TO THE INSTALLER: This manual is the property of the owner and must be affixed near the boiler for future reference. TO THE OWNER: This boiler should inspected annually by a Qualified Service Agency.