Trouble List - Paradox 1686V User Manual

Led keypads
Hide thumbs Also See for 1686V:
Table of Contents

Advertisement

Trouble List

2.5.1 No or Low Battery Trouble [1]
When the [1] button illuminates, the backup battery is
disconnected or the battery voltage is getting low.
2.5.2 Wireless Transmitter Battery Low [2]
When the [2] button illuminates, the battery voltage in one or
more Wireless Transmitters is getting low. Also, the device's
yellow light will flash.
2.5.3 Power Failure [3]
When the [3] button illuminates, the system has detected a loss
of AC power. This trouble usually occurs during a power failure. If
a power failure is not occurring in your establishment and this
trouble appears, contact your Security Company for service.
2.5.4 Bell/PGM2 Disconnected Trouble [4]
When the [4] button illuminates, the bell, siren, or any device
connected to the PGM2 is no longer connected to your alarm
system.
2.5.5 Bell Current Failure [5]
During an alarm, the bell output, which uses a fuseless circuit, will
automatically shut down if the current exceeds its limits. If this
occurs, the [5] button will illuminate. When the system is disarmed,
the current is cut from the bell output and the Trouble warning may
extinguish, but the Trouble may re-occur during the next alarm if
the situation is not corrected.
2.5.6 Auxiliary Current Failure [6]
The auxiliary output, which supplies power to your alarm
system's accessories, uses a fuseless circuit to protect the