HD3 equIP

Audio Settings

Document 800-07361V5 Rev A
07/2013
®
Series H.264 Indoor High Resolution True Day/Night IP Dome Camera User Guide
Figure 4-45
D/N Control Message
3.
Click OK to accept the changes to configure alarm interlock Day/Night switching.
Now any alarm will be generated and appear on the web client screen.
When Alarm Input is set to Normally Open
When the Alarm Input is set to Normally Open, the camera is normally in Day mode if the
camera alarm input connection is opened.
The IR-cut filter will be off (removed), and the camera will switch to Night mode if the
camera alarm input connection is closed (shorted). See
21
for more information about alarm connections.
The IR-cut filter will be on, and the camera will switch to Day mode if the camera alarm
input connect is opened again.
When Alarm Input is set to Normally Closed
When Alarm Input is set to Normally Closed, the camera is normally in Day mode if the
camera alarm input connection is closed (shorted).
The IR-cut filter will be off (removed), and the camera will switch to Night mode if the
camera Alarm input connection is opened.
The IR-cut filter will be on, and the camera will switch to Day mode if the camera alarm
input connection is closed (shorted) again.
The network camera supports bi-directional audio. There are two supported voice band
channels that function in full duplex mode. Connect industry-standard line level audio input
and output to the back of your camera. See
information.
Audio configuration for your network camera is straightforward.
Connecting Alarms
Connecting Audio
on page
on page
21
for more
89