Alarm And Audio; Alarm Settings; Alarm Interlock Day/Night Switching; Figure 4-44 Audio And Io Settings Tab - Honeywell HD3HDIH User Manual

Equip series indoor high resolution true day/night ip dome camera
Hide thumbs Also See for HD3HDIH:
Table of Contents

Advertisement

IP Camera Web Client

Alarm and Audio

Alarm Settings

Alarm Interlock Day/Night Switching

88
Figure 4-44
Audio and IO Settings Tab
Connect external devices such as sirens or flashing lights to the alarm output connector to
signal camera users that an alarm is activated. Set the Alarm Output as Normally Open or
Normally Close. See
Connecting Alarms
When alarm inputs are connected, the camera triggers an alarm only when the normal state
(open or closed) changes. An alarm message appears on the web client screen (see
Figure
4-36) to notify the operator.
The network camera has a D/N Control setting which allows control of the moving IR cut
filter when there is a change in state from Normally Open to Normally Closed or from
Normally Closed to Normally Open for Alarm input (see
more information). In this way, the moving IR cut filter and the day/night operation of the
camera can be interlocked with external lighting changes using a common controller such
as a photocell or timer.
Configuring Alarm Interlock Day/Night Switching:
1.
Select Night Mode On Alarm in the D/N Control field in the Alarm Settings pane of
the IO & Audio tab.
2.
Click Apply. A message appears.
on page
21
for more information.
Connecting Alarms
on page
21
for

Hide quick links: