Supero SuperServer 6026TT-HTF User Manual page 52

Table of Contents

Advertisement

SUPERSERVER 6026TT-HT(R)F/HIBX(R)F/HIBQ(R)F User's Manual
Power Fail LED
The Power Fail LED connection is located
on pins 5 and 6 of JF1. Refer to the table
on the right for pin defi nitions.
Overheat/Fan Fail/PWR Fail/UID LED
Pins 7 and 8 of JF1 are for the Overheat/Fan
Fail/Power Fail and UID LED connections.
The red LED (pin 8) provides warnings of
overheat, fan failure or power failure. The
blue LED (pin 7) is for the UID LED indicator
for the control panel UID button. Refer to the
tables on the right for pin defi nitions.
NIC2 (LAN2) LED
The LED connections for LAN2 are on pins
9 and 10 of JF1. Attach LAN LED cables to
display network activity. See the table on the
right for pin defi nitions.
NIC1 (LAN1) LED
The LED connections for LAN1 are on pins
11 and 12 of JF1. Attach LAN LED cables to
display network activity. See the table on the
right for pin defi nitions.
Wake-On-LAN
The Wake-On-LAN header is located at
JWOL1 on the motherboard. You must
also have a LAN card with a Wake-On-
LAN connector and a cable to use this
feature. See the table on the right for pin
defi nitions.
PWR Fail LED
Pin Defi nitions
Pin# Defi nition
5
6
OH/Fan Fail/ PWR Fail/Blue_UID
LEDPin Defi nitions (JF1)
Pin# Defi nition
7
Blue UID LED/5.5V.SB
8
OH/Fan Fail/PWR Fail/Red UID LED
OH/Fan Fail/PWR Fail
LED Status (Red LED)
State
Off
On
Flashing
NIC2 LED
Pin Defi nitions
Pin# Defi nition
9
10
NIC1 LED
Pin Defi nitions
Pin# Defi nition
11
12
Wake-On-LAN
Pin Defi nitions
Pin# Defi nition
1
+5V Standby
2
Ground
3
Wake-up
5-16
(JF1)
3.3V
PWR Fail LED
Defi nition
Normal
Overheat
Fan Fail
(JF1)
Vcc
Ground
(JF1)
Vcc
Ground
(JWOL1)

Advertisement

Table of Contents
loading