5.4.1 PCB Removal and Replacement

Estimated Time to Repair:
To
From
IRD
LNB
J3
J3
J5
54-0149 Rev. B
1
hour
2
Pan Head Screws
J2
J1
Maintenance
When carrying out maintenance
on the PCB, be sure to not drop
any of the small screws inside the
mechanism. If a screw is lost within
the baseplate, it must be retrieved
to avoid causing any damage when
the unit rotates.
Figure 5-5
TracVision SA is equipped with a
5x220 mm, 4-amp, 250 volt fast-
blow fuse, which is mounted on the
PCB. To access and replace the
fuse, remove the PCB cover.