Maint Port/Baud Rate; Maint Port/Data Bits; Maint Port/Parity; Maint Port/Stop Bits - ADTRAN Express 6100 Manual

Idsl router/bridge
Hide thumbs Also See for Express 6100:
Table of Contents

Advertisement

Chapter 3. Terminal Menu Operation and Structure
The security level for the maintenance port is always set to 0.
This gives full access to all menus.

Maint Port/Baud Rate

Write security: 5; Read security: 5
This is the asynchronous rate that the maintenance port will run. The
possible values are 300, 1200, 2400, 4800, 9600 (def), 19200, 38400,
57600, 115200.

Maint Port/Data Bits

Write security: 5; Read security: 5
This is the asynchronous bit rate that the maintenance port will run.
The possible values are 7 or 8 (def) bits.

Maint Port/Parity

Write security: 5; Read security: 5
This is the asynchronous parity that the maintenance port will run.
The possible values are None (def), Odd, or Even.

Maint Port/Stop Bits

Write security: 5; Read security:5
This is the stop bit used for the maintenance port. The possible values
are 1 (def), 1.5 or 2.
» Configuration/Terminal Mode
This is an activator which places the Express 6100/6120 terminal ses-
sion into a command prompt mode. All menu options are accessible
during this mode. See Terminal Mode Commands on page E-1 for the
command structure and command list. Type
mode and return to the menus.
3-56
Express 6100/6120 User Manual
to leave the terminal
exit
61200176L1-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express 6120

Table of Contents