IP 700 Series Phone Administrator Guide
Parameter
SetupPassword
SipKeepAlive
SipUdpPort
SipTimerBfh
SiteOption
SntpServer
61200770E1-31C
Table 12. Configuration Parameters (Continued)
Value Type
Description
ASCII String
Customizes the MD5 hash of the
password that is entered for restricted
administration settings on the phone.
This password is saved in flash
memory after a value has been
received in a config file so it can be
enforced on subsequent reboots. It is
cleared by the restore factory defaults
command.
Default: 1234
True or False
Enables (true) or disables (false)
session timers.
Default: True
1 to 65536
Sets the port used to receive SIP UDP
traffic.
Default: 5060
3 to 32
Indicates the number of seconds
before the SIP B, F, and H timers
expire. This parameter impacts the
server failover time.
Default: 32
Up to 3 ASCII
Sets the option number that the
Characters
phone will request during DHCP
transactions. If a value other than the
default option 157 is set in a
configuration file, the phone will re-
initiate DHCP procedures using the
new option.
Valid range is between 128 and 254.
Default: 157
Up to 3
Specifies a list of up to 3 time servers
Comma
in FQDN or dotted decimal format,
Separated
from which to retrieve the time and
FQDNs or IP
date information. If from DHCP, only 1
Addresses
server may be specified.
Example:
192.168.0.1, 192.168.0.3,
192.168.0.4
Copyright © 2009 ADTRAN, Inc.
Appendix A. Configuration and Line Parameters
Sources
Config File
Config File
Web Interface
Config File
Web Interface
Config File
Web Interface
Config File
Web Interface
DHCP
Config File
Web Interface