Dell PowerEdge C6220 II Hardware Owner's Manual page 86

Servers
Hide thumbs Also See for PowerEdge C6220 II:
Table of Contents

Advertisement

Emergency Throttling
When the power emergency process starts, an event will be generated by
FCB. And there is a record on the SELs. FCB monitors the error conditions
such as "PSU lost over than the number of Redundant PSU", "PSU fail
event (OC, UV, OT, ...)", "Fan fail", "Ambient temp/Power abnormal",
"MIC card" etc.
1
Enter the server BIOS setup screen.
2
Enter Advanced/Power Management/Chassis Power Management/
Emergency Throttling, and the following options are for Emergency
Throttling functions:
Chassis Level Policy - This is the policy to take effect when the
FCB detects an emergency event. System base on this setting and
have valid actions below:
- Throttling: Power throttles the server until the emergency event
is cleared.
- Power off: Turns the servers off.
Sled Level Policy - System follows <Chassis Level> policy,
<Power Off>, <Throttling> or <Do Nothing> when an
emergency failure occurs. If Sled Level Policy is set with <Chassis
Level>, it will follow the chassis policy.
86
|
Using the System Setup Program

Advertisement

Table of Contents
loading

Table of Contents