Power Capping
1
Enter the server BIOS setup screen.
2
Enter Advanced/Power Management/Chassis Power Management/
Power Capping, and the following options are for Chassis PSU
Configuration functions:
Power Budget –
This is the power budget available. It is the summary of each
PSU's capacity. (i.e. based on the number of PSUs and the max
capacity of each PSU) The max capacity of each PSU is 1100
Watt or 1400Watt supportable. Therefore Power Budget will not
exceed 2660 Watt in this system. (1400 * 2(max number of PSUs
in chassis) * 0.95 = 2660 Watt)
Chassis Level Capping -
Sets as chassis level or sled Level power capping. System
determines power consumption of the chassis and power
consumption of the sleds, and constantly attempts to maintain
the chassis's power consumption below the cap.
Chassis Power Capping -
Determines the power consumption of the chassis. The
maximum value will not be over than the wattage of Power
Budget, and the minimum is 1500.
Sled Power Capping -
Determines the power consumption of the sled. (<0> means to
disable Power Capping Function.) The maximum value is 1000,
and the minimum is 100 if the Power Capping Function is
enabled.