Post End Event - Dell PowerEdge C6220 II Hardware Owner's Manual

Servers
Hide thumbs Also See for PowerEdge C6220 II:
Table of Contents

Advertisement

POST End Event

Byte
Field
1
NetFunLun
2
Platform Event Command
3
Generator ID
4
Event Message
Format Version
5
Sensor Type
6
Sensor Number
7
Event Direction
Event Type
8
Event Data1
9
Event Data2
10
Event Data3
44
|
About Your System
Value
Description
10h
02h
01h
Generated by BIOS
04h
Event Message Format
Revision. 04h for this
specification.
12h
System Event
85h
POST End (depend on
platform)
6Fh
Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code
AXh
01h: OEM System Boot Event
XXh
Bit 7 = Boot Type
0b: PC Compatible Boot
(Legacy)
1b: uEFI Boot
Bit 3:0 = Boot Device
0001b: Force PXE Boot
0010b: NIC PXE Boot
0011b: Hard Disk Boot
0100b: RAID HDD Boot
0101b: USB Storage Boot
0111b: CD/DVD ROM Boot
1000b: iSCSI Boot
1001b: uEFI Shell
1010b: ePSA Diagnostic
Boot
FFh
FFh: Not Present

Advertisement

Table of Contents
loading

Table of Contents