Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C (64 F to 82 F), with
relative humidity at 0 % to 95 %.
The accuracy specifications take the form of:
Maximum voltage between any
terminal and earth ground:
Surge Protection:
W Fuse for A input:
Display:
Temperature:
Temperature Coefficient:
Electromagnetic Compatibility:
Relative Humidity:
Battery Life:
Size, with Holster (H x W x L):
Weight:
Safety Compliance:
Certifications:
Function
1,2
AC Volts
- True RMS
(50 Hz to 500 Hz)
DC Volts
Continuity
Ohms
1.
AC voltage ranges are specified from 5% of range to 100% of range.
2.
Crest factor of
3 at full scale up to 300 V, decreasing linearly to crest factor
3.
The 6000 mV range can only be entered in Manual Range mode. Use the 6000 mVDC range with accessories.
4
600 V
6 kV peak per IEC 61010-1-95
11 A, 1000 V FAST Fuse
Digital:
Bar Graph:
Frequency:
Capacitance:
Operating:
Storage:
0.1 x (specified accuracy)/ °C for <18 °C or > 28 °C
Performance
Noncondensing < 10 °C
0 % to 95 % @ 10 °C to 30 °C
0 % to 75 % @ 30 °C to 40 °C
0 % to 45 % @ 40 °C to 50 °C
Alkaline: 300 hours typical, without backlight
4.6 cm x 9.6 cm x 16.0 cm
350 g
ANSI/ISA-S82.01-1994, CSA C22.2 No 1010.1-92 and IEC 61010-1-95
Overvoltage Category III (CAT III), 600 V
UL (3111), P, CSA, TÜV, ; (N10140)
Range
Resolution
3
6000 mV
1 mV
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
3
6000 mV
1 mV
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
600
1
600.0
0.1
6.000 k
0.001 k
60.00 k
0.01 k
600.0 k
0.1 k
6.000 M
0.001 M
40.00 M
0.01 M
( [ % of Reading ] + [ Counts ] )
6,000 counts, updates 4/sec
33 segments, updates 40/sec
9,999 counts
9,999 counts
10 °C to +50 °C
30 °C to +60 °C
3 V/m is not specified.
Accuracy ± ( [ % of Reading ] + [ Counts ] )
Model 110
1.0 % + 3
0.7 % + 2
Beeper guaranteed on < 20
detects opens or shorts of 250 s or longer.
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
1.5 at 600 V.
Model 111
Model 112
1.0 % + 3
1.0 % + 3
0.7 % + 2
0.7 % + 2
, guaranteed off > 250
0.9 % + 2
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
1.5 % + 3
;