Rebuild Array - Promise Technology FastTRAK66 User Manual

Ultra ata/66 raid card
Hide thumbs Also See for FastTRAK66:
Table of Contents

Advertisement

Rebuild Array <5>
The Rebuild option is necessary to recover from an error in a mirrored disk array.
Note: Drives must be replaced if they contain any physical errors.
Follow these steps before using the <5> Rebuild Array menu option:
1)
From the FastTrak66 Startup BIOS error message, identify which array has
failed.
2)
In the FastBuild
the Channel and ID of the failed drive
3)
Power off and physically remove the failed drive
4)
Replace the drive with an identical model
5)
Continue the restoration process with the <5> option
With a failed drive in a disk array, Rebuild Menu will show the status as "Critical".
FastBuild (tm) Utility 1.xx (c) 1995-99 Promise Technology, Inc.
Array No
RAID Mode
Array 1
Stripe
Array 2
Mirror
Array 3
——
Array 4
——
[ ] Up [ ] Down
TM
FastBuild
Configuration Setup
TM
Setup <3> Define Array, select the failed array and identify
[ Rebuild Array Menu ]
Total Drv
2
2
——
——
[ Keys Available ]
[ESC] Exit
Capacity(MB)
13044
6522
——
——
[Enter] Select
Status
Functional
Critical
——
——
4-10

Advertisement

Table of Contents
loading

Table of Contents