9.7

Event Notification using X-Detect Header

The device supports the sending of notifications to a remote party notifying the occurrence
(or detection) of certain events on the media stream. Event detection and notifications is
performed using the SIP X-Detect message header, and only when establishing a SIP
dialog.
For supporting some events, certain device configurations need to be performed. The table
below lists the support event types (and subtypes) and the corresponding device
configurations, if required:
Events Type
CPT
FAX
PTT
The device reports the following Special Information Tones (SIT) types:
SIT-NC
SIT-IC
SIT-VC
SIT-RO

Table 9-6: Special Information Tones (SITs) Reported by the device

Special
Description
Information
Tones (SITs)
Name
NC1
No circuit found
IC
Operator intercept
VC
Vacant circuit (non
registered number)
RO1
Reorder (system
busy)
SIP User's Manual

Table 9-5: Supported X-Detect Event Types

Subtype
SIT
CED
modem
voice-start
voice-end
First Tone
Frequency
Duration
(Hz)
985.2
913.8
985.2
913.8
412
Required Configuration
SITDetectorEnable = 1
UserDefinedToneDetectorEnable = 1
(IsFaxUsed ≠ 0) or (IsFaxUsed = 0, and
FaxTransportMode ≠ 0)
VxxModemTransportType = 3
EnableDSPIPMDetectors = 1
Second Tone
Frequency
Duration
(ms)
(Hz)
380
1428.5
274
1370.6
380
1370.6
274
1428.5
MP-11x & MP-124
Third Tone
Frequency
Duration
(ms)
(Hz)
(ms)
380
1776.7
380
274
1776.7
380
274
1776.7
380
380
1776.7
380
Document #: LTRT-65412