Ambient Conditions; Overall System Conditions - Bosch Integrus Operation Manual

Language distribution system
Table of Contents

Advertisement

Language Distribution System
LBB 4560/50
Weight incl. 56 receivers
LBB 4560/00
LBB 4560/50
Color
12.3

Ambient Conditions

12.3.1

Overall system conditions

Working conditions
Temperature range:
- transport
- operating and storage
Relative humidity:
- transport
- operating and storage
Safety
EMC emission
EMC immunity
EMC approvals
ESD
Mains harmonics
Environmental requirements
Bosch Security Systems B.V.
11.2 kg (25 lb)
22.3 kg (49 lb)
18.0 kg (40 lb)
Charcoal with grey
Fixed/stationary/transportable
-40 to +70 °C (-40 to 158 °F)
LBB 4560 and LBB 4540 range:
+5 to +35 °C (41 to 113 °F)
LBB 4511/00 and LBB 4512/00 radiators:
+5 to +45 °C (41 to 122 °F)
INT‑TX range:
+5 to +55 °C (41 to 131 °F)
5 to 95%
15 to 90%
LBB 4540 range, LBB 4560/00, LBB 4560/50:
EN60065/CAN/CSA-C22.2 60065 (Canada) /
UL60065 (USA)
LBB 4511/00, LBB 4512/00:
EN60065/CAN/CSA-C22.2 60065 (Canada) /
UL1419 (USA)
INT‑TX range:
EN60065
According to harmonized standard EN 55103‑1
and FCC rules part 15, complying with the limits
for a class A digital devices
According to harmonized standard EN 55103‑2
Affixed with the CE mark
According to harmonized standard EN 55103‑2
According to harmonized
standard EN 55103‑1
Contains no banned substances as specified in
RoHS Directive.