Systems With More Than 4 Carriers And A Radiator Under A Balcony - Bosch Integrus Operation Manual

Language distribution system
Table of Contents

Advertisement

Language Distribution System
Radiator
number
5
6
7
8
9
10
Table 7.4: Calculation of the delay switch positions of a system with two transmitters
7.4.3

Systems with more than 4 carriers and a radiator under a balcony

The next figure illustrates a situation in which a radiation signal delay occurs and which can be
compensated for. For systems with more than four carriers, add one delay switch position per
10 meter (33 feet) difference in signal path length to the radiators which are closest to the
overlapping coverage area. In the next figure the signal path length difference is 12 meter. Add
one delay switch position to the calculated switch position(s) for the radiator(s) under the
balcony.
Figure 7.7: Radiation path length difference for two radiators
Bosch Security Systems B.V.
Trans-
Master-to-
mitter
slave signal
delay [ns]
Master
0
Slave
313
Slave
313
Slave
313
Slave
313
Slave
313
16m
4m
Operation manual
Cable
Total signal
signal
delay [ns]
delay
[ns]
280
0+280=280
168
313+168=481
280
313+280=593
112
313+112=425
168
313+168=481
280
313+280=593
Configuration | en
Signal delay
Delay switch
difference
position
[ns]
593-280=313
313/33=9.48=9
593-481=112
112/33=3.39=3
593-593=0
0/33=0
593-425=168
168/33=5.09=5
593-481=112
112/33=3.39=3
593-593=0
0/33=0
2013.11 | V1.4 |