Follett 12 Installation, Operation And Service Manual page 21

12 series ice and water dispensers
Table of Contents

Advertisement

Diagnostic sequence – Stage 8
If the restart is successful the 20M LED goes off, the 60 minute timer LED (60M) comes on. The 60M
LED remains on for 60 minutes from restart. A lighted 60M LED indicates that the ice machine has experienced
an over-torque condition. If the ice machine runs without problems for 60 minutes and no additional torque
errors occur, the 60M LED goes off and the ice machine continues normal operation.
INPUT
POWER
G
B
W
COMPRESSOR
C
T.O.L.
RED
WHITE
Diagnostic sequence – Stage 9
The second error (2ND) LED comes on if an over-torque condition occurs while the 60M LED is still lighted.
The 2ND LED indicates that two consecutive over-torque situations have occurred. The ice machine will be
shut down at this time and will not restart unless the manual reset button is depressed.
INPUT
POWER
G
B
W
COMPRESSOR
C
T.O.L.
RED
START
RELAY
4
WHITE
12CI400A • 12HI400A
GRD
FAN
BLACK
BLACK
M
BLACK
R
M
1
ORANGE
L
S
S
BLACK
HIGH PRESSURE
SAFETY SWITCH
START
GEAR MOTOR
RELAY
START
4
2
BLACK
3
YELLOW
RUN
T.O.L.
GRD
FAN
BLACK
BLACK
M
BLACK
R
M
1
ORANGE
L
S
S
BLACK
HIGH PRESSURE
SAFETY SWITCH
GEAR MOTOR
START
2
BLACK
3
YELLOW
RUN
T.O.L.
WATER
SENSOR
GRD
L1
L1
WHITE
L2
L2
L2
WHITE
L2
L2
RED
COMPRESSOR
BLACK
FAN
DRIVE
BLACK
BLACK
WATER
SENSOR
GRD
L1
L1
WHITE
L2
L2
L2
WHITE
L2
L2
RED
COMPRESSOR
BLACK
FAN
DRIVE
BLACK
BLACK
PWR
RESET
DR
C
20M
CONTROL
BOARD
60M
2ND
WTR
B-T
B-E
RED
RED
COMPRESSOR
SWITCH
BIN SIGNAL
FROM DISPENSER
BIN T-STAT
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)
PWR
RESET
DR
C
20M
CONTROL
BOARD
60M
2ND
WTR
B-T
B-E
RED
RED
COMPRESSOR
SWITCH
BIN SIGNAL
FROM DISPENSER
BIN T-STAT
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)
21