Error Responses; Using The Command/Response Table - Extron electronics RGB 580xi User Manual

Universal remote interface with audio and adsp
Hide thumbs Also See for RGB 580xi:
Table of Contents

Advertisement

RECONFIG
When the remote interface's RGB video input is disconnected or
the horizontal shift control (H. shift) is adjusted from the AAP
device (RGB 580xi S/CCS AAP and RGB 580xi SI/CCSI AAP),
the interface sends the reconfiguration message. No response is
required from the RS-232 host, but the host may request a new
status listing via the request information command (I/i). See
the command/response table in this chapter for details.
Chn
A contact closure selection has been detected from the remote
AAP contact closure switch (RGB 580xi I AAP and
RGB 580xi SI/CCSI AAP).

Error responses

When the interface receives a valid SIS command, it executes
the command and sends a response to the host device. If
the interface is unable to execute the command because the
command is invalid or it contains invalid parameters, it returns
an error response to the host.
The error response codes and their descriptions are as follows:
E10 – Invalid command
E13 – Invalid value (the number is out of range)

Using the command/response table

The command/response table lists valid command ASCII codes,
the interface's responses to the host, and a description of the
command's function or the results of executing the command.
Lowercase characters are acceptable in the command field only
where indicated. The ASCII to HEX conversion table below is
for use with the command/response table.
ASCII to HEX Conversion Table