Error Responses; Timeout; Using The Command And Response Table - Extron electronics RGB 203 Rxi User Manual

Three input, universal computer-video interface
Hide thumbs Also See for RGB 203 Rxi:
Table of Contents

Advertisement

Error Responses

When the interface receives a valid SIS command, it executes the command and sends a
response to the host device. If the interface is unable to execute the command because the
command is invalid or it contains invalid parameters, it returns an error response to the host.
The error response codes and their descriptions are as follows:
E01 – Invalid input number
E06 – Invalid input selection
E10 – Invalid command
E13 – Invalid value

Timeout

Pauses of 10 seconds or longer between command ASCII characters result in a timeout. The
command operation is aborted with no other indication.

Using the Command and Response Table

The command/response table is on page 24. Lower case letters are allowed in the command
field only as indicated. Symbols are used throughout the table to represent variables in the
command/response fields. Command and response examples are shown throughout the
table. The ASCII to HEX conversion table, below, is for use with the command/response
table.
Symbol definitions
]
=
=
X!
=
X@
=
X#
=
X$
=
X%
=
X^
=
ASCII to HEX Conversion Table
Space
(the number is too large or small)
(the number is out of range/too large)
CR/LF (carriage return/line feed) (0x0D 0A)
space
Input number:
1, 2, or 3
Shift control range: -127 to +127
Controller firmware version (listed to two decimal places, "x.xx")
xxx.xx: frequency in Hz or kHz
Input selected: 1 - 3 (for input 1 through 3)
Part number
.
RGB 203 Rxi • SIS Commands