Hardware Related Commands - CalAmp 819-GPRS series User Manual

Gsm gprs serial cellular data modem
Table of Contents

Advertisement

Hardware Related Commands

The AT Commands described in this section are related to the modems's hardware interface.
A brief description of hardware related commands are provided in Table 9.14. For futher information,
refer to the Siemens TC65/MC75 AT Command Set document available from Siemens.
Table 9.14: Hardware Related Commands
Command
Description
Real Time Clock:
Format is "yy/mm/dd,hh:mm:ss", where the characters indicate the two last
digits of the year, followed by month, day, hour, minutes, seconds; for example
6th of July 2005, 22:10:00 hours equals to "05/07/06,22:10:00" Factory default
is "02/01/01,00:00:00"
Write command:
=<time>
AT+CCLK
• <time> is retained if the device enters the Power Down mode via AT^SMSO.
• <time> will be reset to its factory default if power is totally disconnected. In
this case, the clock starts with <time>= "02/01/01,00:00:00" upon next power-
up.
• Each time TC65 is restarted it takes 2s to re-initialize the RTC and to update
the current time. Therefore, it is recommended to wait 2s before using the
commands AT+CCLK and AT+CALA (for example 2s after ^SYSSTART has been
output).
Set alarm time:
The write command can be used to set an alarm time in the ME or to clear a
AT+CALA
programmed alarm. When the alarm time is reached and the alarm is executed
the ME returns an Unsolicited Result Code (URC) and the alarm time is reset to
"00/01/01,00:00:00".
Set critical operating temperature presentation mode or query temperature:
Use this command to monitor the temperature range of the module. The write
command enables or disables the presentation of URCs to report critical
temperature limits.
Write command:
=0 Presentation of URCs is disabled (except for <m> equal to -2 or +2).
AT^SCTM
=1 Presentation of URCs is enabled.
Read command:
-2 Below lowest temperature limit (causes immediate switch-off)
-1 Below low temperature alert limit
0
1
2
Normal operating temperature
Above upper temperature alert limit
Above uppermost temperature limit (causes immediate switch-off)
001-0003-829 Revision 1