2.3

Configuring default gateway setting

This section will describe how to configure the default gateway for the system.
Beginning in privileged EXEC mode, follow these steps to configure default gateway from
out-of-band management interface:
Command
Step 1
configure
Step 2
oob protocol
<bootp|dhcp|dhcp6|none>
Step 3
oob ip <ipaddr> <netmask>
Step 4
oob gateway <gateway>
Step 5
exit
Step 6
show oob
To configure the default gateway for the out-of-band management interface, use oob
gateway global configuration command. To display IP setting of out-of-band management
interface, use show oob privileged EXEC command.
In this example, out-of-band management interface is configured with a fixed IP address
10.1.20.1 and default gateway 10.1.20.254.
(BX900-CB1)#configure
(BX900-CB1)(Config)#oob protocol none
Changing protocol mode will reset ip configuration.
Are you sure you want to continue? (y/n)y
(BX900-CB1)(Config)#oob ip 10.1.20.1 255.255.255.0
(BX900-CB1)(Config)#oob gateway 10.1.20.254
(BX900-CB1)(Config)#exit
(BX900-CB1)#show oob
IP Address..................................... 10.1.20.1
Subnet Mask.................................... 255.255.255.0
Default Gateway................................ 10.1.20.254
IPv6 Address................................... FE80::21E:68FF:FE85:F760/64
OOB interface Configured Protocol.............. None
Burned In MAC Address.......................... 00:1E:68:85:F7:60
(BX900-CB1)#
2011 Fujitsu Technology Solutions
©
Purpose
Enter global configuration mode.
To set IP management interface to use
bootp, dhcp, dhcpv6 or none.
To set a fixed IP address and net mask for
management interface.
To set the default gateway address.
Return to privileged EXEC mode.
Verify the configuration.