POSIFLEX XP-3000 Series User Manual

POSIFLEX XP-3000 Series User Manual

Xp-3000/3300 series fan free touch terminal
Hide thumbs Also See for XP-3000 Series:

Advertisement

XP-3000/3300 Series
Fan Free Touch Terminal
User's Manual
FCC Notes:
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions manual, may cause interference to radio communications.
It has been tested and found to comply with limits for a Class A digital device pursuant to subpart
J of Part 15 of FCC Rules, which are designed to provide reasonable protection against
interference when operated in a commercial environment. Operation of this equipment in a
residential area is likely to cause interference in which case the user at his owns expense will be
required to take whatever measures to correct the interference.
Warranty Limits:
Warranty terminates automatically when any person other than the authorized technicians opens
the machine. The user should consult his/her dealer for the problem happened. Warranty voids if
the user does not follow the instructions in application of this merchandise. The manufacturer is by
no means responsible for any damage or hazard caused by improper application.
About This Manual:
Posiflex has made every effort for the accuracy of the content in this manual. However, Posiflex
Technology, Inc. will assume no liability for any technical inaccuracies or editorial or other errors
or omissions contained herein, nor for direct, indirect, incidental, consequential or otherwise
damages, including without limitation loss of data or profits, resulting from the furnishing,
performance, or use of this material.
This information is provided "as is" and Posiflex Technology, Inc. expressly disclaims any
warranties, expressed, implied or statutory, including without limitation implied warranties of
merchantability or fitness for particular purpose, good title and against infringement.
The information in this manual contains only essential hardware concerns for general user and is
subject to change without notice. Posiflex Technology, Inc. reserves the right to alter product
designs, layouts or drivers without notification. The system integrator shall provide applicative
notices and arrangement for special options utilizing this product. The user may find the most up
to date information of the hardware from: http://www.posiflex.com or http://www.posiflex.com.tw
or http://www.posiflexusa.com
All data should be backed-up prior to the installation of any drive unit or storage peripheral.
Posiflex will not be responsible for any loss of data resulting from the use, disuse or misuse of this
or any other Posiflex product.
All rights are strictly reserved. No part of this documentation may be reproduced, stored in a
retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying,
or otherwise, without prior express written consent from Posiflex Technology, Inc. the publisher of
this documentation.
© Copyright Posiflex Technology, Inc. 2010
All brand and product names and trademarks are the property of their respective holders.
15480900030
P/N:
Rev.: B0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XP-3000 Series and is the answer not in the manual?

Questions and answers

ali omar
April 7, 2025

I need the value of the DC voltage of the Board POSIFLEX XP-3000e-e

1 comments:
Mr. Anderson
April 9, 2025

The POSIFLEX XP-3000/3300 system can supply +5V DC through COM2 and COM3 via BIOS settings, and +12V DC through jumper settings. The VGA port can also deliver +12V DC through BIOS settings.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for POSIFLEX XP-3000 Series

  • Page 1 All data should be backed-up prior to the installation of any drive unit or storage peripheral. Posiflex will not be responsible for any loss of data resulting from the use, disuse or misuse of this or any other Posiflex product.
  • Page 2: About This Product

    You may apply ammonia-based glass cleaner only on the screen surface. ABOUT THIS PRODUCT Posiflex XP-3000/3300 series presents a whole new generation POS terminal, which is a combination of touch screen, printer, MSR, and the most reliable FanFree system. This integrated solution of XP-3000/3300 series not only less cable connection, but also carrying a brilliant performance to user in order to face the busiest situation.
  • Page 3: Product Pictures

    INTRODUCTION PRODUCT PICTURES Front Views Side Views Rear & Bottom Views Page 2...
  • Page 4: Parts Identification

    PARTS IDENTIFICATION LCD display with touch panel Printed paper exit LED indicator for power and printer status Paper feed button Power switch Brightness control buttons Magnetic Stripe Reader(Option) LCD adjustable Holder Lock/Release button for tilt angle adjust 10. Printer cover 11.
  • Page 5 Storage device 2.5" SATA HDD or SSD HDD Power switch On the top side Power Saving Suspension mode Indicator LED and Power ON/ standby, bi-color LED, Printer Error (RED), Control panel Paper Out (RED), paper feed / power ON switch / Brightness switch control buttons.
  • Page 6 Indicator LED and Power ON/ standby, bi-color LED, Printer Error (RED), Control panel Paper Out (RED), paper feed / power ON switch / Brightness switch control buttons. Fan-Free system OS support Windows XP Pro, WEPOS, POSReady, Win 7, Linux Power Supply Power adaptor, 80W Power adaptor, 120W 3"...
  • Page 7: Brightness Control

    INSTALLATION GUIDES Hardware Power Switch and printer paper feed The power switch located in the front bezel of main unit. It is a pushbutton switch and controls the power on/off of the whole system. Also, next to the power and status indicators is the paper feed button for integrated printer.
  • Page 8: Display Issues

    Posiflex USB Touch Manager A program named “Posiflex USB Touch Manager” and a right-click sticky button tool in the program group “Posiflex USB Touch Tools” is installed in Page 7...
  • Page 9: Printer Operation

    Windows system with a USB interface touch panel controller. This program can also be obtained by download from the POSIFLEX web site. Mouse Emulation Touch Function The touch panel in XP-3000/3300 system uses internal USB interface as standard and occupies no external port.
  • Page 10 Step C: Pull up the printer cover. Step D: Loading the paper roll and please notice that the paper roll’s orientation should be face the printer head. Step E: Please pull the paper longer then paper exit and close the printer cover at the centre of front and please watch your finger during this step in order to reduce hurt occur.
  • Page 11 adjustment and a sensor block in the wall. Turn the thumb wheel to adjust the appropriate position of sensor block. The default height of near end sensor is the lowest position. Self Test For XP-3000/3300 series printer’s test mode, please turn off the terminal first.
  • Page 12 The MSR in XP-3000/3300 series reads the ISO or JIS-II magnetic stripe card without driver. Yet, there is a “Posiflex USB MSR Manager” program provided to control some parameter configuration for ISO MSR.
  • Page 13 UPS Battery (Option) CAUTION: Please notice that to connect the UPS battery only before power up the system or when system is switch off. Always disconnect the UPS battery when the system is to be left powered off for more than few days. When the XP-3000/3300 system is ordered with the UPS battery, the UPS battery is in the carton at delivery.
  • Page 14 In XP-3000/3300 system, COM2 and 3 can supply a +5 V DC through system BIOS setting and +12V through jumper setting. The VGA port can delivery +12 V power through system BIOS setting for Posiflex LCD display monitor. Page 13...
  • Page 15: Preparing The Main Unit

    Nevertheless, except Posiflex peripheral device, do not connect any other device to this port before the power in this port is disabled. CAUTION: Please turn off the system power first! Then hold the base and move the terminal carefully. Connecting Cables To have the terminal ready for operation, please connect all required cables to the appropriate connectors.
  • Page 16 Rear Mount Upgrade Kit There are plenty of upgrade kits of XP-3000/3300 series for choice. To install these upgrade kits, please refer the installation guide of each kit. For some interface such as serial ports and VGA ports, please remember to enable the power supply of the main unit for the upgrade kit if the serial or VGA interface model is used.
  • Page 17: System Recovery

    The RJ11 connector in I/O area of a XP-3000/3300 system can be used for controlling most of the common cash drawers available on the market. However, it is most recommended to use Posiflex CR-2000 or CR-2200 or CR-3100 or CR-3200 or CR-4000 or CR-4100 or CR-4210 or CR-6310 for best compliance to operate the opening mechanism and to monitor the drawer open status.
  • Page 18: Operating System Installation

    Then follow instructions from your system integrator for software recovery. Operating System Installation This product is highly professionalized equipment. The installation of an OS into a machine without any preloaded OS could be a major difficulty for average user or obstacle by possibly unintentional negligence even for PC veterans to accomplish such a task.
  • Page 19: Power Supply

    unexpected result even if the battery is not in work. The UPS battery can support basically the data preservation and smooth operation during intermittent or up to 30 minutes. Battery replacement: In the preloaded OS for XP system, there is a built in utility Power Manager that will interface the UPS battery monitor status with user.
  • Page 20: Storage Device

    +5V/+12V power supply settings is supported in system jumper setting and printer parameter setting. However, such support is limited to the application of specific Posiflex peripherals and must be disabled when the Posiflex peripherals are disconnected. Failure to follow the discipline would result in...