I Setup Layer 3 Switching (L3SW)

Layer 3 Switching refers to a class of high-performance routers optimized for wire speed Ethernet routing and switching ser-
vices. It is required to support Internet Group Management Protocol (IGMPv2).
Based on the sample described in "Digital Video Encoder Devices" and "Digital Video Decoder Devices", the following table
contains Ethernet ports information for the L3SW.
Port #
IP Address
1
192.168.1.1
2
192.168.2.1
3
192.168.3.1
4
192.168.4.1
5
192.168.200.1

I Admin Console

Admin Console is a system database management software. The software operates in the Microsoft
Refer to the Admin Console User's Guide for details.
To connect a personal computer (PC) with the CPU, perform the following. (Refer to the Admin Console User's Guide for
details.)
1. Install the admin console on a PC. (Refer to the Admin Console User's Guide for details.)
2. Enter the CPU IP address in the tool's CPU screen. (The CPU screen appears when you launch the tool for the first time.)
PC
with Admin Console

I Time Management Utility

Time Management Utility (TMU) is software used for time configuration. The software operates in the Microsoft Windows envi-
ronment. We recommend that the Time Management Utility be installed on the same computer that runs the admin console.
To connect the TMU to the CPU, you should select IPA setup from the TMU main menu, and enter the IP address of the CPU.
Refer to Time Management Utility User's Guide for details.
Connection
Encoder #1,2
Encoder #3,4
Decoder #1
Decoder #2
WJ-MPU955A