Power-Airflow Dual Flaps, Wide Angle Louvers And Auto-Swing - Daikin CTXS09GVJU Service Manual

Super multi nx g-series
Hide thumbs Also See for CTXS09GVJU:
Table of Contents

Advertisement

Main Functions
1.2
Power-Airflow Dual Louvers, Wide Angle Louvers and
Auto-Swing
Power-airflow
The large louvers send a large volume of air downwards, providing optimum control for cooling,
Dual Louvers
heating, and dry mode.
Heating Mode
During heating mode, the large louver directs warm air downwards where it then can pervade the
entire room.
Cooling Mode
During cooling mode, the louver retracts into the indoor unit. Then, cool air can pervade the entire
room.
Wide-Angle
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees a
Louvers
comfortable air distribution.
Auto-Swing
In case of the Wall Mounted Indoor Unit:
The following table explains the auto-swing process for heating, cooling, dry and fan :
Outline of 3-D
In case of the Wall Mounted Indoor Unit:
Airflow
Alternative repetition of vertical and horizontal swing motions enables uniform airconditioning of the
entire room.
Detail of the
When the horizontal and vertical louvers are both set to auto mode, the airflows are alternated,
Action
providing a full range of air conditioning. The order of swing motion is such that it turns
counterclockwise, starting from the right upper point as viewed to the front side of the indoor unit.
26
Vertical Swing (up and down)
Heating
Cooling
10˚
15˚
15˚
40˚ 10˚
55˚
55˚
40˚
(R2813)
Dry
35˚
35˚
(R2814)
(R2815)
(R1024)
SiUS12-814
Horizontal Swing
(right and left)
Fan
Heating, Cooling
55˚
55˚
(R2816)
Function and Control
(R2817)