WARNING!!
Always disconnect the power supply be-
fore cleaning or servicing the oven.
WARNING!!
If the oven needs to be moved, the gas
must be turned off and disconnected from
the unit before removing the restraint. Re-
connect the restraint after the oven has
been returned to its original location.
Follow this recommended cleaning schedule for
proper oven performance.
Daily:
1. Clean the conveyor belt using a wire brush. Al-
low any foreign material to drop into the crumb
pans.
2. Remove the product stop and both crumb
pans from the ends of the conveyor.
3. Empty and clean the crumb pans with a hot
water/detergent mix. Rinse with clean water.
Every Three Months:
1. Unplug the power cord.
2. Disconnect the gas. Be sure that the oven
control cables have 2-3 feet of slack
3. Clean the cooling fan louvers on both sides of
the oven with a soft brush.
Figure 24

Maintenance

Every Six Months:
1. Remove the product stop and both crumb
pans and tensioners from the ends of the con-
veyor.
2. Remove both upper end plugs. Loosen the
wing nuts on the bottom of each end plug.
3. Remove both lower end plugs.
4. Remove the conveyor as follows:
a.) Loosen the four 1/4" hex bolts securing
the conveyor belt motor to the control box.
Slide the motor forward. Remove the drive
chain from the conveyor drive spocket.
b.) Using needle-nose pliers, remove the
conveyor belt inner and outer master
links.
21

Cleaning

Figure 25
Figure 26

Advertisement

Table of Contents
loading