Note
Contact your installer/dealer
if this occurs.
Trouble Beeps
and Trouble
Messages
14
Sensor
DTIM
Initiate a sensor test.
Door/Window
Open the secured door or window.
Carbon Monoxide Alarm Unplug the CO Alarm. Plug it back in, wait 10 seconds then
press the TEST/RESET button until the unit beeps 8 times.
Glass Guard
Tap the glass 3 or 4 inches from the sensor.
Motion Sensor
Avoid the Motion Sensor field of view for 5 minutes, then enter
its view.
Rate-of-Rise Heat
Rub your hands together until warm, then place one hand on
Detector
the detector for 30 seconds.
Shock
Tap the glass twice, away from the sensor. Wait at least 30 sec-
onds before testing again.
Smoke
Press and hold the test button until the system sounds transmis-
sion beeps.
Panic Buttons
Press and hold the appropriate panic button(s) for 3 seconds.
KeyChain Touchpad
Press and hold LOCK and UNLOCK simultaneously for 3 sec-
onds.
Remote Handheld
Press and hold the 2 EMERGENCY buttons simultaneously for
Touchpad
3 seconds.
Hardwire Loops
Open the secured door or window.
If a Wireless Sensor Does Not Test Successfully
If the panel sounds less than the required number of beeps when a zone/sensor is tripped, this
indicates wireless sensor signal strength is below acceptable limits. Distance from the receiver
and/or installation environment are most likely affecting the sensor's signal strength.

Phone Communication Test

The purpose of this test is to verify that the connection between the central monitoring station
and your system are working properly.
Most phone tests take only a few minutes, however, your system will try for up to 15 minutes to
establish a connection.
To perform a phone test:
1. Press
until phone test is displayed.
2. Press
to initiate a phone test. Within 5 minutes the panel will display TEST PASS or TEST
FAIL.

Exiting User Programming Mode

After all user programming is completed, use the following procedure to exit programming
mode.
To exit programming mode:
1. Press
until
EXIT
2. Press
to exit. The current time is displayed.
Or
If instructed by your installer/dealer to initiate a downloader session, enter your primary
access code.
When your system detects a problem, it lets you know by sounding trouble beeps from panel, and
by displaying status messages on the panel display (see Appendix B).
Table 6: Sensor "Tripping" Instructions
is displayed.
Do This
Number
of Beeps
7-8
7-8
7-8
7-8
7-8
7-8
7-8
7-8
7-8
7-8
7-8
1