ALIGNING BLADE GUARD
ASSEMBLY
WARNING
!
MAKE CERTAIN THAT THE SAW IS DISCONNECT-
ED FROM THE POWER SOURCE.
Fig. 7
B
1. Raise blade guard away from the table and hold
the anti-kickback fingers (A) out of the way.
SEE FIG. 7.
2. Using an accurate straight edge, check to see that
the straight edge rests against the splitter (B) and
against the face of the saw blade (C).
3. If an adjustment is necessary, refer back to the
section titled BLADE GUARD ASSEMBLY in the
ASSEMBLY section of this manual.
TABLE INSERT ADJUSTMENT
WARNING
!
MAKE CERTAIN THAT THE SAW IS DISCONNECT-
ED FROM THE POWER SOURCE.
1. Lower blade completely.
2. Place the open end of the insert under the splitter
and lower the insert into the opening.

ADJUSTMENTS

C
A
3. Adjust the table insert flush with the table by turning
four leveling screws and using a straight edge.
SEE FIG. 8.
Fig. 8
MITER GAUGE OPERATION
1. Operate Miter gauge by loosening lock knob(A), pull
out spring loaded plunger (B) and rotate miter
gauge body (C) to desired angle. SEE FIG 9.
Fig. 9
A
B
2. Release plunger and tighten lock knob.
3. Adjust fit of the miter bar (D) in the miter slot by
adjusting set screws (not shown) located in the side
of the tie bar in or out.
Note: Always make test cuts. Do not rely solely on
miter gauge indictor marks.