I N S TA L L AT I O N
USE AN AUTHORISED PERSON
As stated in the local municipal building codes and other relevant statutory regulations.
• Wiring connections must be in accordance with AS/NZS 3000 Wiring Rules and any
particular conditions of the local authority.
• Refer to data plate for rating information and circuit diagram. The data plate is positioned
behind the bottom of the oven door. The circuit diagram is positioned on the top panel of
the appliance.
• An all pole disconnect functional switch should be provided near the appliance in an
accessible position. Refer to AS/NZS 3000 clause 4.3.11
• Wiring should be protected against mechanical failure. Refer to AS/NZS 3000 clause 3.9
• A means of disconnection with a contact separation of at least 3mm must be supplied in
the fixed wiring.
• To gain access to the mains connection terminals, remove the rear access cover by
unscrewing the 2 screws.
NOTE: Where connection is made to a multi-phase 240V supply, the bridge piece should be
removed from between the active connections.
IMPORTANT: This appliance must be properly earthed.
• Do not lift the appliance by the door handles.
• Prepare the cupboard opening to match your appliance measurements. (See diagrams).
• Slide appliance into the cupboard, ensuring that the supply cable (where fitted) does not
kink.
• To prevent tipping, use the screws supplied to secure your oven into the cupboard. Use just
2 screws for single cavity ovens and 4 srews for dual cavity. Remove the bottom door in
dual cavity ovens to provide access to the bottom 2 screwing points (see illustration on
page 32).
• For appliances fitted with a supply flexible cord, if the cord is damaged, it must be
replaced by the manufacturer or its service agent or similarly qualified person in order to
avoid a hazard. The plug must be accessible after installation.
• Where the appliance is built into a cabinet, the cabinet material must be capable of
withstanding 70°C. Installation into low temperature tolerant cabinetry (e.g. vinyl coated)
may result in deterioration of the low temperature coating by discolouring or bubbling.
• If the appliance is installed adjacent to vinyl-wrapped surfaces, use an installation kit
available from the vinyl-wrap supplier.
• Electrolux Home Products cannot accept responsibility for damage caused by installation
into low temperature tolerant cabinets.
• After installation, test and ensure that the appliance operates correctly before handing it
over to the customer.
CAUTION: To avoid any potential hazard, you must follow our instructions below
when you install your appliance. Failure to install the appliance correctly could
invalidate any warranty or liability claims and lead to prosecution.