Introduction - Martin Magnum Pro 2000 User Manual

Smoke machine with remote control unit
Hide thumbs Also See for Magnum Pro 2000:
Table of Contents

Advertisement

Before attempting any of the following ensure that the machine is
disconnected from any mains power and cooled down.
1 Remove the fluid tank from the machine.
2 Remove the two Philips screws that secure the top-cover over the heating element.
3 Slide the cover backwards until the thermo-switch becomes accessible. The thermo-
switch is located on the mid, left hand side of the heating element with two wires
attached.
4 Press the plastic button on the thermo-switch, thereby resetting this switch.
5 Re-assemble the fixture before connecting to the mains.
NOTE
If the thermo-switch should interrupt repeatedly, then contact your Martin dealer
for service.