Poor fixing
Step
Cause
Fuser unit
pressure is high
1
Fuser unit failure
2
LVPS PCB failure Is the problem solved
3
HVPS PCB
4
failure
Main PCB failure Is the problem solved
5
■ Completely blank
Step
Cause
Developing bias
voltage
1
conduction
failure
Scanner harness
of the laser unit
2
connection
failure
Laser unit failure
3
HVPS PCB
4
failure
Main PCB failure Is the problem solved
5
User Check
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Check
Is the problem solved
after replacing the
position of the pressure
roller?
Is the problem solved
after replacing the fuser
unit?
after replacing the LVPS
PCB unit?
Is the problem solved
after replacing the
HVPS PCB ASSY?
after replacing the main
PCB ASSY?
User Check
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Check
Are the electrodes on
the drum unit and
machine body dirty?
Is the scanner harness
of the laser unit
connected securely?
Is the problem solved
after replacing the laser
unit?
Is the problem solved
after replacing the
HVPS PCB ASSY?
after replacing the main
PCB ASSY?
1-32
Result
Remedy
Replace the position of the
pressure roller.
Yes
(Refer to Fig.
1-4.)
Replace the fuser unit.
Yes
Replace the LVPS PCB
Yes
unit.
Replace the HVPS PCB
Yes
ASSY.
Replace the main PCB
Yes
ASSY.
Result
Remedy
Clean both electrodes.
(Refer to Fig. 1-1, Fig.
Yes
Reconnect the scanner
harness of the laser unit.
No
Replace the laser unit.
Yes
Replace the HVPS PCB
Yes
ASSY.
Replace the main PCB
Yes
ASSY.
1-2.)