Brother DCP-7030 Service Manual page 267

Laser multi-function center
Hide thumbs Also See for DCP-7030:
Table of Contents

Advertisement

<WSW23>
Selector No.
Starting point of training check
1
(TCF)
2
Allowable training error rate
3
4
Decoding error rate for
transmission of RTN
5
6
Not used.
7
8
Limitation of attenuation level
Note:
Selector 8 is not applicable to the French models.
• Selector 1: Starting point of training check (TCF)
At the training phase of receiving operation, the called station detects for 1.0 second a
training check (TCF) command, a series of zeros which is sent from the calling station for
1.5 seconds to verify training and give the first indication of the acceptability of the line.
This selector sets the starting point from which the called station should start counting
those zeros. If this selector is set to "0," the called station starts counting zeros 100 ms
after the head of a series of zeros is detected.
If it is set to "1," the called station starts counting zeros upon detection of 10-ms successive
zeros 50 ms after the head of a series of zeros is detected. In this case, if the detection of
10-ms successive zeros is too late, the data counting period will become less than 1.0
second, making the called station judge the line condition unacceptable.
• Selectors 2 and 3: Allowable training error rate
The called station checks a series of zeros gathered in training (as described in Selector 1)
according to the allowable training error rate set by these selectors. If the called station
judges the line condition to be accepted, it responds with CFR; if not, it responds with FTT.
• Selectors 4 and 5: Decoding error rate for transmission of RTN
The machine checks the actual decoding errors and then transmits an RTN according to
the decoding error rate (Number of lines containing an error per page ÷ Total number of
lines per page) set by these selectors.
• Selector 8: Limitation of attenuation level
Setting this selector to "0" limits the transmitting level of the modem to 4 dB. This setting
has priority over the settings selected by WSW02 (selectors 5 through 8) and WSW13
(selectors 5 through 8).
Function
0: 0 From the head of a series of zeros
1: From any arbitrary point
No. 2 3
No. 4 5
App. 1-28
Setting and Specifications
0 0: 0 %
0 1: 0.5 %
1 0: 1 %
1 1: 2 %
0 0: 16 %
0 1: 14%
1 0: 10 %
1 1: 8 %
0: Yes
1: No
Confidential