8.36 TONER SENSOR PCB UNIT ASSY
(1) Remove the Taptite bind B M3x10 screw, and then remove the Link stopper and the
Toner sensor PCB unit ASSY from the Main body.
(2) Remove the PT sensor holder from the Toner sensor PCB unit ASSY.
2
Toner sensor PCB
unit ASSY
<Left side>
PT sensor holder
Hook
Fig. 3-96
3-92
Taptite bind B M3x10
Link stopper
Toner sensor PCB
unit ASSY
1
Confidential