Step 3: Minimum Flame Adjustment - Bertazzoni MAS304DFMXE Installation, Use & Care Manual

30” freestanding dual fuel ranges
Table of Contents

Advertisement

 
STEP 2: SURFACE BURNERS 
To replace the nozzles of the surface burners, lift 
up the burners and unscrew the nozzles shipped 
with the range using a 7 mm {socket wrench).  
Replace nozzles using the conversion set supplied 
with  the  range  or  by  a  Bertazzoni  authorized 
parts  warehouse.  Each  nozzle  has  a  number 
indicating its flow diameter printed on the body. 
Consult the table on page 20 for matching nozzles 
to burners.  
STEP 3: MINIMUM FLAME ADJUSTMENT 
WARNING! 
These adjustments should be made only for use 
of the appliance with natural gas. For use with 
liquid propane gas, the choke screw must be 
fully turned in a clockwise direction. 
SURFACE BURNERS 
1. Light  one  burner  at  a  time  and  set  the  knob 
to the MINIMUM position (small flame). 
2. Remove the knob. 
3. The  range  is  equipped  with  a  safety  valve. 
Using a small‐size slotted screwdriver, locate 
the  choke  valve  on  the  valve  body  and  turn 
the choke screw to the right or left  until the 
burner flame is adjusted to desired minimum. 
 
 
 
 
 
 
 
4. Make  sure  that  the  flame  does  not  go  out 
when  switching  quickly  from  the  MAXIMUM 
to the MINIMUM position. 
 
 
21
 
 
 
 
 

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mas365dfmxeMas30 4 dfm xe

Table of Contents