Pressure Regulator; Gas Conversion; Step 1: Pressure Regulator; Step 2: Surface Burners - Bertazzoni MAS304DFMXE Installation, Use & Care Manual

30” freestanding dual fuel ranges
Table of Contents

Advertisement

 
PRESSURE REGULATOR  
Since  service  pressure  may  fluctuate  with  local 
demand,  every  gas  cooking  appliance  must  be 
equipped  with  a  pressure  regulator  on  the 
incoming  service  line  for  safe  and  efficient 
operation. 
The  pressure  regulator  shipped  with  the 
appliance  has  two  female  threads  ½"  NPT.  The 
regulator shall be installed properly in order to be 
accessible  when  the  appliance  is  installed  in  its 
final position.  
Manifold pressure should be checked with a 
manometer and comply with the values indicated 
below: 
Natural gas  4.0" W.c.P.  
LP/Propane  11.0" W.C.P.  
Incoming line pressure upstream from the 
regulator must be 1" W.c.P. higher than the 
manifold pressure in order to check the 
regulator.  
The regulator used on this range can withstand a 
maximum input pressure of 1/2 PSI (14.0" W.c.P.) 
If the line pressure exceeds that amount, a step‐
down regulator is required. 
The  appliance,  its  individual  shut‐off  valve,  and 
the  pressure  regulator  must  be  disconnected 
from  the  gas  line  during  any  pressure  testing  of 
that  system  at  pressures  in  excess  of  1/2  psig 
(3.45 kPa). 
The  individual  manual  shut‐off  valve  must  be  in 
the  OFF  position  during  any  pressure  testing  of 
the  gas  supply  piping  system  at  test  pressures 
equal to or less than ½ psig (3.45 kPa). 
 
 
 
 
 
Before carrying out this operation, disconnect 
the appliance from gas and electricity. 
Gas conversion shall be conducted by a factory‐
Call the customer service hotline to identify a 
factory‐trained professional near your home. 
The  gas  conversion  procedure  for  this  range 
includes 6 steps: 
1. Pressure regulator 
2. Surface burners 
3. Adjustment of minimum setting 
The  conversion  is  not  completed  if  all  6  steps 
have not been concluded properly. 
Before performing the gas conversion, locate the 
package  containing  the  replacement  nozzle 
shipped  with  every  range.  IMPORTANT:  Each 
nozzle has a number indicating its flow diameter 
printed on the body. Consult the table on page 20 
 
for matching nozzles to burners. 
Save the nozzles removed from the range for 
future use.  
 
The pressure regulator supplied with the 
appliance is a convertible type pressure regulator 
for use with Natural Gas at a nominal outlet 
pressure of 4" w.c. or LP gas at a nominal outlet 
pressure of 11" w.c. and it is pre‐arranged from 
the factory to operate with one of these 
gas/pressure as indicated in the labels affixed on 
the appliance, package and Instruction booklet. 
To convert the regulator for use with other liquid 
propane LP gas: 
1. Unscrew by hand the upper cap of the 
regulator, remove the white plastic 
attachment from the cap, reverse its 
direction and screw it again firmly against the 
cap. The white plastic attachment has arrows 
indicating the position for natural gas (NAT) 
and LP gas (LP). 
2. Screw by hand the metal cap in the original 
position on the regulator.  
 
20
GAS CONVERSION 
WARNING! 
trained professional. 
STEP 1: PRESSURE REGULATOR 

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mas365dfmxeMas30 4 dfm xe

Table of Contents