GAS CONVERSION

STEP 6: MINIMUM FLAME ADJUSTMENT

WARNING
These adjustments should be made only
for use of the appliance with natural gas.
For use with liquid propane gas, the choke
screw must be fully turned in a clockwise
direction.
SURFACE BURNERS
Light one burner at a time and set the knob to the
MINIMUM position (small flame).
Remove the knob.
The range is equipped with a safety valve. Using a small-
size slotted screwdriver, locate the choke valve on the
valve body and turn the choke screw to the right or left until
the burner flame is adjusted to desired minimum.
Make sure that the flame does not go out when switching
quickly from the MAXIMUM to the MINIMUM position.
A
For the gas valve of dual burner the choke valve is located
on the valve body (Fig. 31 ), the A screw adjust the outer
ring, the B screw adjust the inner ring.
OVEN BURNER
Reinstall the oven door.
Set the oven temperature control knob to the MAXIMUM
setting.
Close the oven door and operate the oven for at least 10
minutes.
Set the knob to the MINIMUM setting.
Remove the knob.
With a slotted screwdriver turn the choking screw (by-pass
screw at the left side of the thermostat bar) and, while
observing the flame at the same time through the bottom
oven porthole, evaluate the consistency of the flame so it
remains on when switching quickly from MINIMUM to
MAXIMUM setting.
Fig. 30
BROILER BURNER
The broiler burner always operates at maximum,
B
therefore no minimum adjustment is required.
When gas conversion is complete, complete the enclosed
conversion label and place it next to the rating label.
Fig. 31