Cleaning/descaling and sanitizing

Periodic cleaning/descaling and sanitizing of Follett's ice and water dispenser and ice machine system is required to
ensure peak performance and delivery of clean, sanitary ice. The recommended cleaning procedures that follow should be
performed at least as frequently as recommended and more often if environmental conditions dictate.
Cleaning of the condenser can usually be performed by facility personnel. Cleaning/descaling and sanitizing of the ice
machine system should be performed by your facility's trained maintenance staff or a Follett authorized service agent.
Regardless of who performs the cleaning, it is the operator's responsibility to see that this cleaning is performed according
to the schedule below. Service problems resulting from lack of preventive maintenance will not be covered under the
Follett warranty.
Recommended cleaning/descaling and sanitizing intervals*
Symphony
Drain Line
Drain Pan/Drip Pan
Exterior
Condenser
Dispenser and Components
Ice Machine
Chilled Water Accessory
Transport Tube
Ice Storage Area/Bin
*
Ice machine and dispenser must be cleaned and sanitized prior to start-up.
Weekly
§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser.
Dispenser drain pan and drain line
1. Pour 1 gal. (3.8 L) of hot tap water into drain pan to fl ush drains.
Splash panel front, SensorSAFE infrared dispensing
1. Deactivate dispensing by pressing and releasing clean switch located on left side of unit under top front cover.
2. Clean lens and splash panel front using a soft cloth and mild, non-abrasive, non-chlorine based cleaner.
3. Reactivate dispensing by pressing and releasing clean switch again.
Monthly
§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser.
Condenser (air-cooled ice machine only)
1. Use a vacuum cleaner or stiff brush to carefully clean condenser coils of lint and debris to ensure optimal
performance.
Semi-Annually (more often if conditions dictate)
§ A cleaning/descaling and sanitizing procedure should always include both the ice machine and dispenser; ice
machine should be cleaned and sanitized fi rst, followed by the dispenser.
§ Icemaking system can be cleaned/descaled in place.
To ensure that your ice machine and dispenser are cleaned/descaled and sanitized properly, proceed as follows:
1. Clean/descale the ice machine
2. Sanitize the ice machine
3. Clean/descale the dispenser
4. Sanitize the dispenser
16
Frequency
weekly
weekly
as needed
monthly (air-cooled only)
semi-annually
semi-annually
semi-annually
semi-annually
semi-annually
CAUTION!
CAUTION!
25CT/HT/CR/HR/FB and 50CT/HT/CR/HR/FB