Clearances To Combustibles - Quadra-Fire 43M-ACC-MBK Owner's Manual

4300 wood stove series advanced combustion control (acc) installation and operation
Table of Contents

Advertisement

R
B. Clearances to Combustibles (UL and ULC)
BACKWALL / SIDEWALL
CORNER INSTALLATION
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
INSTALLATION: Full Vertical OR Horizontal with Minimum 2 FT Vertical Off Stove Top
SINGLE WALL PIPE
Flat Top Model
Step-Top Model
DOUBLE WALL PIPE
Flat Top Model
Step-Top Model
INSTALLATION: 90° Elbow Off Top of Stove Through Backwall
DOUBLE WALL PIPE
Flat Top Model
Step-Top Model
INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listed
factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove
shall be no more than 48 inches (1220mm) with a minimum height of 49.5 inches (1283mm) to top of unit, and the referenced clearances.
*In Canada must comply with CAN/ULC-S269 M87 for the 650
DOUBLE WALL PIPE
Flat Top Model
Step-Top Model
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
September 1, 2008
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
90° OFF TOP
UP & OUT CEILING
CLEARANCE
STOVE TO CEILING
CLEARANCE
A
B
15.5 (394) 11.75 (298) 24.5 (622) 14.5 (368)
15.5 (394) 11.75 (298) 24.5 (622) 14.5 (368)
9 (229)
5.25 (133)
24.5 (622) 14.5 (368)
7.5 (191)
3.75 (95)
22 (559)
8.5 (216)
6 (152)
24.5 (622)
7.5 (191)
4 (102)
19 (229)
13 (330)
10 (254)
24.5 (622) 14.5 (368)
7.5 (191)
3.75 (95)
22 (584)
C
D
E
10 (254)
2 (51)
10 (254)
11.75 (298)
2 (51)
15 (381)
10 (254)
9 (229)
2 (51)
o
C Factory-built chimney.
N/A
11.75 (298)
N/A
NOTE: Service Space
In order to replace the tube channel assembly a clearance
of 19 inches (48mm) is required on the right side of stove
in order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon-
nected from the chimney to proceed with the tube replace-
ment. See Figure 36 on page 36.
7037-135E
4300 Wood Stove Series (ACC)
ALCOVE SIDE VIEW
ALCOVE TOP VIEW
F
G
17.5 (445) 53.5 (1359)
12 (305)
49.5 (1283)
17.5 (445) 53.5 (1359)
12 (305)
49.5 (1283)
17.5 (445)
53.5(1359)
12 (305)
49.5 (1283)
N/A
53.5 (1359)
N/A
49.5 (1257)
A
B
H
12 (305)
12 (305)
12 (305)
5 (127)
N/A
N/A
12 (305)
5 (127)
Page 11