E. Air Controls; Burn Rates & Operating Efficiency - Quadra-Fire 43M-ACC-MBK Owner's Manual

4300 wood stove series advanced combustion control (acc) installation and operation
Table of Contents

Advertisement

R
2. Burn Rate Air Control
This air supply enters at the upper front of the firebox, near the
top of the glass door. This preheated air supplies the neces-
sary fresh oxygen to mix with the unburned gases, helping
to create second, third and fourth combustions. This air is
regulated by the Burn Rate Air Control. There are four settings
High, Medium-High, Medium-Low and Low. When the control
is raised all the way up it is on the High setting and when
pushed all the down it is on the Low setting. Figure 27.1.
F. Burn Rates and Operating Efficiency
For maximum operating efficiency
1. This appliance has a timer system (ACC) that operates
the stove at its maximum efficiency removing any guess
work for the homeowner. Follow the instructions below
for each burn rate for the Start-Up Air Control and Burn
Rate Air Control. Figure 27.1.
2. Burn dry, well-seasoned wood.
Burn Rates
1. Starting a Fire and Reloading
Open both controls fully by raising the Burn Rate Air
Control all the way up until it stops and slide the Start-up
Air Control back until it stops. After loading the stove with
wood and starting the fire, set both controls to the desired
setting by following the burn rate instructions below.
NOTE: These are approximate settings, and will vary with
type of wood or chimney draft. Due to altitude and other
environmental circumstances, this operational information is
a guideline only.
2. High Burn Rate - Maximum Heat
Raise the Burn Rate Air Control all the way up until it stops
(top marker) to a fully open position. Slide the Start-Up Air
Control all the way back until it stops (HI marker) and leave
it there. This setting over-rides the timer system (ACC) so
you must monitor the fire closely while in this setting.
WARNING
Risk of Fire.
When set on High Burn Rate and over-riding
the Automatic Combustion Control system an
overfire situation can occur and may result in a
chimney fire.
Overfiring will void the stove warranty.
3. Medium-High Burn Rate
Raise the Burn Rate Air Control all the way up until it
stops (top marker) to a fully open position. Slide the
Start-Up Air Control all the way back until it stops (HI
marker) and then pull forward until it stops. This activates
the timer system (ACC).
September 1, 2008
-
15,000 to 30,000 BTU/hr
4. Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr
Raise the Burn Rate Air Control up to the bottom of
the middle marker and stop. Slide the Start-Up Air
Control all the way back until it stops (HI marker) and
then pull forward until it stops. This activates the timer
system (ACC).
5. Low Burn Rate - Below 10,000 BTU/hr
Leave the Burn Rate Air Control at the bottom marker.
Slide the Start-Up Air Control all the way back until it
stops (HI marker) and then pull forward until it stops.
This activates the timer system (ACC).
HIGH
LOW
Burn Rate
Air Control
Start-Up Air
Control
REAR AIR
Closed
After activating the timer (ACC), if the control is placed
within the rear air section on the label it will allow rear air
to enter the firebox. This will not interfere with the timer
gradually closing the front air channel in 25 minutes. If
control is set on "HI" it over-rides the timer (ACC).
igure 27.1
F
Operate appliance on High Burn 15 minutes a
NOTE:
day to help keep flue/chimney clean.
7037-135E
4300 Wood Stove Series (ACC)
Shown with Side
Shield Removed
Low (Closed)
High (Open)
Front Air Channel
Operated by Timer
Rear Air Channel
Operates independently
from Timer
START-UP
"HI" setting
Wide
over-rides
Open
Timer
Timer
Timer Manual
Shut-off
HI
Page 27