Negative Pressure - Quadra-Fire 43M-ACC-MBK Owner's Manual

4300 wood stove series advanced combustion control (acc) installation and operation
Table of Contents

Advertisement

4300 Wood Stove Series (ACC)
C. Negative Pressure
Draft is the pressure difference needed to vent appliances
successfully. Considerations for successful draft include:
• Preventing negative pressure
• Location of appliance and chimney
Negative pressure results from the imbalance of air avail-
able for the stove to operate properly. Causes for this imbal-
ance include:
• Exhaust fans (kitchen, bath) etc.)
• Range hoods
• Combustion air requirements for furnaces, water
heaters and other combustion appliances
• Clothes dryers
• Location of return-air vents to furnace or air condi-
tioning
• Imbalances of HVAC air handling system
• Upper level air leaks
• Recessed lighting
• Attic hatch opening
Duct leaks
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Windward
Recommended:
Outside Air Intake
on windward side
Figure 6.1
Page 6
Recommended Location:
• Above peak
Recommended Location:
• Inside heated space
• Above peak
Marginal Location:
• Below peak
Recommended:
• Insulated exterior chase
in cooler climates
Multi-level Roofs
7037-135E
To minimize the affects of negative air pressure the following
must be considered:
Install the outside air kit. Install the intake on the
side of the house towards prevailing winds during the
heating season.
Ensure adequate outdoor air is supplied for combus-
tion appliances and exhaust equipment.
Ensure furnace and air conditioning return vents are
not located in the immediate vicinity of the appli-
ance,
Avoid installing the appliance near doors, walkways
or small isolated spaces.
Recessed lighting should be of "sealed can" design;
attic hatches weather stripped or sealed; and attic
mounted duckwork and air handler joints and seams
taped or sealed.
WARNING
Asphyxiation Risk.
• Negative pressure can cause spillage of com-
bustion fumes, soot and carbon monoxide.
• Appliance needs to draft properly for safety.
Marginal Location:
• Wind loading possible
NOT recommended:
Outside Air Intake
on leeward side
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Leeward
September 1, 2008
R

Advertisement

Table of Contents
loading

This manual is also suitable for:

43st-acc43m-acc-mbk

Table of Contents