Step 10
After selecting a value for the upper limit, press the STORE button to save it. "STORED" will
flash briefly on the display.
Turn the PARAMETER SELECT control one step clockwise to access the Lower Limit
Step 11
parameter (for PARA1).
Use the PARAMETER ADJUST control to select the lowest value which the parameter is not
Step 12
to fall below through MIDI control changes.
After selecting a value for the lower limit, press the STORE button to save it. "STORED" will
Step 13
flash briefly on the display.
Selecting a lower limit value that is greater than the upper limit value will invert the response
of the controller - i.e. the toe position of the expression controller will provide the minimum
value, while the heel position will provide the maximum value.
NOTE: Steps 1-13 are repeated seven times for a total of eight controllers. To exit Controller
Assign at any time, turn either the PRESET or FUNCTION SELECT control. Only changes
that have been stored will be saved after exiting the Controller Assign function.