Step 5
Press the STORE button on the Voodu Valve to initiate the data dump. As the Voodu Valve
performs the dump, it will display "XXX DUMPED" - where "XXX" = the number of the data
string currently transmitting (i.e. strings 1-254 are presets, titles, controller information and 2-
tap delay information; string 255 contains program mapping information; and string 256
contains miscellaneous information. Contact Rocktron Corporation for information on how to
receive a detailed MIDI spec).
Step 6
After the Voodu Valve displays "TRANS COMPLETE", stop the sequencer. The sequencer
should have recorded all of the data that was dumped from the Voodu Valve. Keep this data stored
on a disk in a safe place. Turn the PARAMETER SELECT control to continue.
TRANSMITTING VOODU VALVE