Snmp Targetaddr - Supermicro Intelligent Switch User Manual

Table of Contents

Advertisement

17.6 snmp targetaddr

This command configures the SNMP target address. The no form of the command removes the
configured SNMP target address.
snmp targetaddr <TargetAddressName> param <ParamName> {<IPAddress> |
<IP6Address>} [timeout <TimeoutValue(1-1500)] [retries <RetryCount(1-3)]
[taglist <TagIdentifier | none>] [{volatile | nonvolatile}]
no snmp targetaddr <TargetAddressName>
Syntax Description
TargetAddressName - Name of the Target address (host)
Param - SNMP parameter Name
IPAddress/ IP6Address - IP/IP6 Address of the host
Timeout - The time the SNMP agent waits for a response from the SNMP Manager before
retransmitting the Inform Request Message
retries - The Maximum number of times the agent can retransmit the Inform Request Message
taglist - Tag Identifier
volatile | nonvolatile - Storage type
Mode
Global Configuration Mode
Defaults
ParamName - Internet
IPAddress - 10.0.0.10
Taglist - snmp
Storage type - volatile
Example
smis(config)# snmp targetaddr issmgr param issd 10.0.0.10 taglist
mytag nonvolatile
Target param must have been configured.
Related Commands
show snmp targetaddr - Displays the configured SNMP target Addresses
Release :
431 / 913
1.0

Advertisement

Table of Contents
loading

Table of Contents