Figure 11: Fxo Lines Configuration Definitions - Grandstream Networks GXW-410 User Manual

Analog ip gateway 4 or 8 fxo ports w/video surveillance
Hide thumbs Also See for GXW-410:
Table of Contents

Advertisement

Figure 11: FXO Lines Configuration Definitions

When set to Y, Current Disconnect is enabled. Certain PSTN Cos require
Enable Current
Disconnect
this to be enabled, in order to realize correct disconnect for PSTN side.
Default it Y.
AC Termination
Selects the impedance of the analog Line connected to the FXO port on the
GXW-410x.
Impedance
Silence Timeout
Terminate call after long silence detected. Default is 60 seconds, max
65536.
Default value is 100ms.
DTMF Digit
Length
DTMF Digit
Default value is -11dB.
Volume
DTMF Dial Pause Default value is 100ms.
Wait Dial-tone
It is recommended to set this to Y in case Dialing stage is set to 1.
Dialing Stage
Dialing stage can be set to 1 or 2. Note:- When set to 1, the Server needs
to be configured to allow forwarding and receipt of SIP messages from GXW
IP address directly.
Off-hook Auto
This parameter allows users to configure a User ID or extension number to
Dial
be automatically dialed upon off-hook. Please note only the user part of the
SIP address needs to be entered here. The GXW-410x will automatically
append the '@' and host portion of the corresponding SIP address.