Memory Maps
6.1.13 PLD Data Code Register
The MVME3100 PLD provides a 32-bit register that contains the build date code of the
timers/registers PLD.
Table 6-14 PLD Data Code Register
REG
PLD Data Code Register - 0xE200000C
BIT
31:24
FIELD
yy
OPER
R/W
RESET
xxxx
yy: Last two digits of the year
mm: Month
dd: Day
vv: Version
6.1.14 Test Register 1
The MVME3100 provides a 32-bit general-purpose read/write register that can be used by
software for PLD test or general status bit storage.
Table 6-15 Test Register 1
REG
Test Register 1 - 0xE2000010
BIT
31:0
FIELD
TEST1
OPER
R/W
RESET
0000
TEST1: General-purpose 32-bit read/write field.
118
23:16
15:8
mm
dd
MVME3100 Single Board Computer Installation and Use (6806800M28C)
7:0
vv